Fibson homePlan my room
Menu

Acoustic panels for restaurants, cafes and bars

Dining rooms where guests can talk without leaning in, planned from the ceiling down.

Plan my dining room
A felt bread basket holds a folded napkin and a round loaf, with a small lit candle beside it on the corner of a table.
Diners' top complaint
Noise (24% in Zagat's 2018 survey)
Usual plan
Clouds or baffles first, then wall and art panels
Checked in the plan
Sprinklers, finish class, cleaning, clearances
Example room
2.3 s down to about 1.0 s (fictional)

Owners usually notice the problem the same way: guests lean in, servers repeat orders, regulars ask for the quiet corner, and a room that sounded fine at four in the afternoon is exhausting by eight. This page, written for owners, managers and their designers, explains why dining rooms get loud as they fill, what to look at in yours and what a panel plan usually contains.

Why dining rooms get loud

In Zagat’s 2018 national dining survey, noise was the most bothersome issue, at 24%, just ahead of service at 23%. Measurements show how loud it gets:

  • Hodgson and colleagues (2007) found that, across ten eating establishments, the levels diners and employees were exposed to ranged from 45 to 82 dBA.
  • To and Chung (2014) measured peak-hour levels of 66.7 to 82.6 dBA across types of restaurant in Hong Kong, and found the levels depended only on how densely the room was occupied.
  • In New York City, health department researchers (Spira-Cohen and colleagues, 2017) measured 59 loud venues and found a median of 92 dBA; restaurants and bars averaged 91 dBA.

The Hong Kong finding is the key one. In a hard room, each conversation adds to a background that everyone else then has to talk over. People raise their voices, the background rises with them, and the room keeps climbing until it settles at a level that tires guests and staff alike. Panels do not stop anyone talking. They shorten how long each voice keeps bouncing around the room, so less of it piles up behind the next one and the climb starts from a lower base.

Who you lose matters too. Bottalico and colleagues (2022) found that background levels below 50 dBA let senior customers keep their vocal effort low and their understanding of conversation high, which kept their willingness to spend time and money high. The World Health Organization projects that by 2050 nearly 2.5 billion people, 1 in 4, will live with some degree of hearing loss. A room where people can talk is becoming an accessibility feature.

We will not promise a decibel figure for a full room; the crowd, the music and the kitchen decide too much of it. The plan gives you the arithmetic behind the change in reverberation.

What to look for in your room

  • The ceiling. Height, material and what hangs from it: sprinkler heads, lights, ducts and diffusers. Exposed decks in taprooms and converted buildings are frequent offenders.
  • Floors, glass and the bar. Concrete, tile or sealed wood, a storefront window, a tiled or mirrored back bar.
  • Sources of noise. An open kitchen, an espresso machine, the dish return, the sound system.
  • Seats and peak hours. How many people at the busiest hour, and where they sit.

The restaurant acoustics checklist walks through each item.

What a restaurant plan usually includes

  • The ceiling first. Ceiling clouds over the tables, or rows of ceiling baffles under a high or exposed deck.
  • Wall panels at seated ear height along banquettes and long walls.
  • Printed art panels where a wall should carry art or the brand, from images you own or have licensed.
  • An estimate for the empty room and notes on the full one, with an optional quieter section.

Cleaning and kitchen-adjacent finishes

We keep panels out of cooking and prep areas. Near the pass, the bar or a coffee station we choose finishes that can be vacuumed or wiped, mount them above splash and chair height, and include the fabric maker’s cleaning instructions. Grease from an open kitchen settles on everything nearby, so panels close to it go higher or farther away.

Ceilings with sprinklers

Clouds and baffles hang below the sprinkler heads, so they must not interfere with sprinkler coverage. The plan draws every hanging panel against your heads, lights and diffusers, for your sprinkler contractor and the local fire official to check. Hanging hardware must suit the structure above, and the building code requires interior finish to stay attached at 200°F for at least 30 minutes.

Fire class and accessibility

The International Building Code treats paneling applied for acoustical correction as interior finish. In the 2021 model text, as printed in Seattle’s adopted code, Table 803.13 calls for Class C finish in rooms of Group A-1 and A-2 assembly occupancies when the building is sprinklered and Class B when it is not, with a footnote permitting Class C in places of assembly with 300 or fewer occupants; lobbies in Groups A-1, A-2 and A-3 must be at least Class B. The local building official decides. Your plan names the class we expect and the core or fabric maker’s ASTM E84 report behind each finish. A class applies only when the report covers the assembly as built (core, fabric and adhesive together), and Fibson has not yet tested its finished panels. Wall panels along walkways stay within the ADA 4 inch protrusion limit, and anything hung over a walkway keeps 80 inches clear.

Example (fictional). Not a Fibson project. A 60-seat dining room, 40 by 30 ft with an 11 ft ceiling, volume 13,200 cu ft, unoccupied and furnished. Mid-frequency (500 to 1,000 Hz) coefficients are planning assumptions, not test results.

Surface or panel group Area (sq ft) Coefficient Sabins
Floor, sealed wood 1,200 0.07 84.0
Ceiling, painted gypsum board 1,200 0.05 60.0
Storefront glass 220 0.12 26.4
Walls, painted gypsum board 1,320 0.05 66.0
Tables, chairs and bar (allowance) 40.0
Total now 276.4
16 ceiling clouds, 4 by 4 ft, over the tables 256 0.90 230.4
14 fabric wall panels, 2 by 4 ft, seven on each long wall 112 net 0.75 84.0
4 printed art panels, 4 by 6 ft, two on each long wall 96 net 0.75 72.0
Total with panels 662.8

Now: RT60 = 0.049 × 13,200 ÷ 276.4 = 646.8 ÷ 276.4 = 2.34 seconds. With panels: 646.8 ÷ 662.8 = 0.98 seconds. Wall and art panels are assumed at 0.80, replacing gypsum at 0.05, so each square foot adds a net 0.75.

The ceiling does the most work: clouds alone bring the room to 1.28 seconds, against 1.79 for the wall panels alone. The target of about 1 second is a planning choice, since no code sets one for restaurants; for reference, LEED v4.1 lists under 0.8 seconds for hotel meeting or banquet rooms. The wall panels project about 2.5 inches with mounting, within the ADA limit, and the clouds hang with at least 80 inches clear.

The example room lets you switch each panel group on and off. When you are ready, send us your room with photos of the ceiling and every wall and your busiest-hour seat count.

Send us the room

Room size, a few photos and what happens in the space. We reply with questions or an outline of the plan.

Plan my dining room