Acoustic panels for offices, restaurants and homes
One way of planning a room, applied to rooms that work very differently.
Plan my room
- Same in every room
- Measure, estimate, set a target, place panels
- What changes
- Use, occupancy, finish rules, cleaning, ceiling height
- What you get first
- A written room plan before anything is made
Offices
Less ring in open-plan work areas, with honest limits on speech privacy.
Meeting rooms
Shorter echo in conference, huddle and video-call rooms, planned around the seats.
Restaurants, cafes and bars
Dining rooms where guests can talk without leaning in, planned from the ceiling down.
Homes
Calmer open-plan rooms, with panels that look like they belong on the wall.
Home offices
Less echo on calls and recordings, from a few panels in the right places.
A dining room on a Friday night, an open office, a meeting room on its fourth video call of the day and a living room with a wood floor and a wall of glass all sound different. They go wrong in the same way, though: hard surfaces send sound back into the room faster than anything soaks it up, so each voice is still bouncing around when the next one starts. So we plan every room the same way. We work out its volume and surfaces, estimate how long it rings now, agree a target that suits its use and place panels where they do the most work. The room plan shows each step, whether the room seats sixty people or one.
What changes from room to room
The arithmetic stays the same. The decisions around it do not.
- Use. A room for video calls needs a shorter ring than a taproom, where some buzz is part of the appeal. LEED v4.1 lists under 0.6 seconds for conference and teleconference rooms and under 0.8 seconds for an open-plan office without sound masking. No code sets one for a restaurant or a home; there the target is a planning choice we explain in writing.
- Occupancy. People absorb sound and also make it. A full dining room is louder than the empty one we estimate; the plan says which condition its numbers describe.
- Finish rules. The building code treats acoustic panels as interior finish, and the fire class required in a room depends on its occupancy and on whether the building has sprinklers. Your local building official decides; the plan names the class we expect and the test report behind each finish we propose.
- Cleaning. Beside a bar or a coffee station, panels need finishes that can be vacuumed or wiped, placed above splash height. At home the concern is dust, pets and small children.
- Ceiling height. A standard ceiling suits ceiling clouds or wall panels; a high or exposed one suits rows of ceiling baffles. Anything hung over a walkway keeps at least 80 inches clear underneath, the ADA minimum vertical clearance.
Start with your room
Pick the space closest to yours above. Each page covers what usually goes wrong, what to look for, what a plan tends to include and a short fictional example with the arithmetic shown. The example room works one fictional 60-seat dining room through in full, from 2.3 seconds to about 1 second, and the reverberation time calculator runs the same numbers on yours.
If your room fits none of these, send it to us anyway. We will tell you plainly whether panels are the right tool for it.
Send us the room
Room size, a few photos and what happens in the space. We reply with questions or an outline of the plan.