Fibson homePlan my room
Menu

Acoustic panels for open offices

Less ring in open-plan work areas, with honest limits on speech privacy.

Plan my office
Rows of felt coffee mugs stand on a long shared desk, each curl of steam stopping short under a soft panel hanging above.
Main problem
Speech that rings and carries between desks
Usual plan
Clouds or baffles first, then wall panels
Reference figure
Under 0.8 s (LEED v4.1, open plan, no masking)
Panels alone
Do not make conversations private

Open-plan offices are hard on the ear for two reasons that are easy to mix up. The room rings, because the floor, ceiling, glass and desks are hard. And voices carry, because nothing stands between the person on a call and the person trying to write three desks away. Panels deal well with the first problem and only partly with the second. This page is for office managers, facilities teams and the designers who work with them, and it keeps the two problems apart so you spend money on the one you actually have.

What goes wrong, and why it matters

The US General Services Administration’s workplace guide, Sound Matters, calls acoustic problems “a leading source of employee dissatisfaction in offices”. In one of its baseline surveys, 60% of people said they could get more done if it were quieter.

The research is most specific about speech. Intelligibility is measured with the speech transmission index (STI), from 0 (no words can be made out) to 1 (perfectly clear). Haapakangas, Hongisto and Liebl (2020) report that cognitive performance begins to fall above roughly STI 0.21 and reaches its largest drop at about 0.44. In an earlier open-office laboratory study, Haka and colleagues (2009) found performance on several tasks was worse at STI 0.65 than at 0.10 or 0.35. Put simply, the more clearly you can follow a colleague’s conversation from your desk, the harder it is to concentrate.

The open plan also does not reliably produce the conversation it was meant to encourage. Bernstein and Turban (2018) studied workplaces that moved to open offices and found that face-to-face interaction fell by about 70%. Noise is not the only reason people stop talking at their desks, but it is one a facilities team can do something about.

Absorb, block, cover

GSA frames office noise control as “the ABC’s of noise control: Absorb, Block, Cover”. Panels are the A.

  • Absorb. Ceiling and wall panels shorten the ring and stop voices from reaching distant desks by way of the ceiling. GSA’s guide asks for ceilings with an NRC of at least 0.9 in open-plan areas, which tells you where the biggest surface, and usually the biggest gain, is.
  • Block. Walls, taller screens, distance and layout. A panel overhead does nothing about the direct path from one mouth to the next ear.
  • Cover. Sound masking: a steady, designed background sound that makes nearby speech harder to follow. We do not supply it.

Panels on their own do not create speech privacy. By removing the reverberant wash around a voice, they can even make a nearby conversation a little clearer. If the complaint is that people can follow every word at the next desk, the space needs blocking and masking as well as absorption, and we will say so in writing rather than sell you more panels than the room needs.

For the ring itself, LEED v4.1 gives a useful reference: under 0.8 seconds at 500, 1,000 and 2,000 Hz for an open-plan office without masking.

What to look for in your office

Walk the floor at a busy hour and note:

  • The ceiling. Exposed concrete deck, painted drywall or acoustic tile, its height, and what is up there: lights, sprinkler heads, diffusers, cable trays.
  • The floor. Polished concrete and vinyl plank reflect almost everything; carpet tile helps at mid and high frequencies.
  • Glass. Window walls and glass meeting-room fronts are large, hard and usually parallel to something.
  • Where people talk. Call-heavy teams, the coffee point, reception, the corridor past the meeting rooms.
  • What is already soft. Upholstered chairs, desk screens, existing acoustic tile. Leaving these out overstates the problem.

The open office acoustics checklist turns this into a list you can fill in and send.

What an office plan usually includes

  • The ceiling first. Ceiling clouds over desk clusters where the ceiling is a normal height, or rows of ceiling baffles where it is high or exposed and services run through it. The plan shows every panel against your lights, sprinklers and diffusers.
  • Wall panels at seated head height on walls and columns next to desk clusters, in fabric-wrapped or felt finishes, with printed art panels in breakout areas where a wall should carry more than color.
  • Break and kitchen areas treated as their own zone, since they are often the loudest part of the floor.
  • A note on what panels will not do, with the blocking and masking measures we think the space needs.
  • Code and accessibility notes. Panels count as interior finish under the building code, so the plan names the fire class we expect your occupancy to need and the core or fabric maker’s report behind each finish. Fibson has not yet tested its finished panels. Wall panels along walkways stay within the ADA’s 4 inch limit for objects with leading edges between 27 and 80 inches above the floor, and anything hung over a walkway keeps 80 inches clear. See materials and safety and the ADA protrusion checker.

The panel count comes from arithmetic, not a coverage rule of thumb. The panel quantity calculator shows the same steps, and acoustic design explains how we turn them into a layout.

Example (fictional). Not a Fibson project. A 10-desk open office, 40 by 25 ft with a 10 ft painted drywall ceiling, a vinyl plank floor and 200 sq ft of window glass. Volume 10,000 cu ft. The mid-frequency coefficients are planning assumptions, not test results.

Surface Area (sq ft) Coefficient Sabins
Floor, vinyl plank 1,000 0.03 30.0
Ceiling, painted drywall 1,000 0.05 50.0
Walls, painted drywall 1,100 0.05 55.0
Window glass 200 0.12 24.0
Desks, chairs and storage (allowance) 45.0
Total 204.0

RT60 = 0.049 × 10,000 ÷ 204.0 = 2.4 seconds.

The plan adds 14 ceiling clouds, 4 by 8 ft, over the desk clusters (448 sq ft, 45% of the ceiling, at an assumed 0.90: 403.2 sabins) and 12 fabric wall panels, 2 by 4 ft, at seated head height (96 sq ft at an assumed 0.80 replacing drywall at 0.05, net 0.75: 72.0 sabins). New total 679.2 sabins; RT60 = 0.049 × 10,000 ÷ 679.2 = 0.72 seconds, under the LEED v4.1 open-plan figure. The person on a call two desks away is still heard directly, so if privacy mattered here the plan would add a masking and layout note.

If you are planning a fit-out, or living with one that echoes, send us the floor with photos of the ceiling and a rough desk layout. Meeting rooms on the same floor follow a stricter reference; see meeting rooms.

Send us the room

Room size, a few photos and what happens in the space. We reply with questions or an outline of the plan.

Plan my office