ADA protrusion checker for acoustic panels
Check a panel's depth and hanging height against the ADA limits.
Plan my room
- Wall panels
- 4 in maximum with a leading edge 27 to 80 in up
- Overhead
- 80 in minimum vertical clearance
- Rules
- 2010 ADA Standards, sections 307.2 and 307.4
- Not
- Legal advice or a code approval
Calculator
Acoustic panels go where people walk: along restaurant aisles, in office corridors, over the route to the restrooms. The 2010 ADA Standards for Accessible Design limit how far objects may stick out into a walking route at heights a person using a cane may not detect, and how low anything may hang overhead. This checker applies both rules to a wall panel and to a cloud or baffle.
The two rules
Section 307.2 covers protrusion. Objects with leading edges more than 27 in and not more than 80 in above the floor “shall protrude 4 inches (100 mm) maximum horizontally into the circulation path”. A circulation path is the standards’ term for a walking route.
Section 307.4 covers headroom: “Vertical clearance shall be 80 inches (2030 mm) high minimum.” A cloud or baffle over a walking route needs its lowest point, including hardware and anything hung from it, at 80 in or higher.
How to use it
- Leading edge height. For a wall panel this is usually its bottom edge, measured from the finished floor, in inches.
- Projection. Measure from the wall surface to the panel’s face, including the cleat, standoffs or air gap. A 2 in panel on 1/2 in of hardware projects 2.5 in.
- Overhead clear height. For a cloud or baffle over a walking route, enter the height of its lowest point above the floor. Enter 0 if there is none.
How the checker decides
- Leading edge at or below 27 in: the 4 in limit does not apply.
- Leading edge above 80 in: the 4 in limit does not apply.
- Leading edge in between: a projection of 4 in or less is within the limit; more than 4 in exceeds it.
- Overhead: 80 in or more meets the vertical clearance; anything lower is too low over a walking route.
Worked example
Example (fictional). In the example room, a 60-seat dining room that is not a Fibson project, fabric wall panels hang at seated ear height with their bottom edge 36 in above the floor and project about 2.5 in with mounting. The defaults also place a cloud’s lowest point at 96 in. The results read:
- Wall panel leading edge: 36.0 in
- Wall panel projection: 2.50 in
- Wall panel result: “Projects 4 in or less: within the limit”
- Overhead panel clear height: 96.0 in
- Overhead result: “80 in or more: meets the vertical clearance”
Now try a 2 in printed art panel on 2.5 in standoffs. Enter a projection of 4.5 in and the wall panel result changes to “Projects more than 4 in between 27 and 80 in: exceeds the limit”. The fix is to drop the standoffs, use a thinner panel, raise it above 80 in or move it off the walking route.
Where panels run into trouble
- Art panels on standoffs. Thick printed panels standing off the wall pass 4 in quickly. See printed art panels.
- Panels on an air gap. A gap improves low-frequency absorption and adds depth; the air gap calculator shows the trade.
- Deep slats and layered felt. Wood slat panels on a felt backer and stacked felt shapes add depth from their build.
- Low clouds and baffles. In rooms with low ceilings, a deep baffle or a cloud on long cables uses up the 80 in quickly. See ceiling clouds and the baffle layout calculator.
A panel over a fixed banquette, or behind furniture that keeps people away from the wall, may not be on a circulation path at all. That is a judgment for whoever approves the plan, not something to assume.
Not legal advice
This checker applies two sections of the 2010 ADA Standards to the numbers you enter. It is a planning aid, not legal advice and not a code approval. Your state or city may enforce its own accessibility code or a different edition, and other sections of the standards, the building code and the fire code can apply to the same wall. The local building official decides. When we plan a room, the room plan notes the projection and clearance of each panel group so you can show them to whoever approves the work.
Next steps
Plan mounting depth and hardware with installation support, and send the room with Plan my room when you want the placement drawn and checked for you.
Send us the room
Room size, a few photos and what happens in the space. We reply with questions or an outline of the plan.