Fibson homePlan my room
Menu

Baffle layout calculator

How many baffles fit your ceiling, in how many rows.

See ceiling baffles
A felt seed tray seen from above with neat parallel rows of young green seedlings.
You enter
Ceiling size, baffle size, spacing and margin
You get
Rows, baffles per row, total and face area
Absorption
From the sabins per baffle in the test report
Check
Sprinklers, lights, structure and 80 in clear

Calculator

The example values describe a fictional 60-seat dining room. Replace them with your own; results update as you type. Nothing you enter leaves your browser.

Results

Rows across the width
9
Baffles in each row
7
Total baffles
63
Exposed face area (both sides)
504 sq ft
Ceiling area
1,200 sq ft

Rows run along the length at the spacing you set, measured center to center. Baffle makers usually publish absorption per baffle (sabins per unit) rather than an NRC; use that figure with the panel quantity calculator.

Ceiling baffles are vertical panels hung in rows from the ceiling, edge down. They suit rooms with high or open ceilings, exposed deck or ductwork, and spaces where the walls are mostly glass, shelving or kitchen. This calculator works out how many fit a ceiling at a given spacing, so you can see the scale of a layout before anyone draws it.

How to use it

  1. Enter the ceiling’s length and width in feet. Rows run along the length.
  2. Enter the baffle’s length and its height, meaning how far it hangs down.
  3. Enter the row spacing, measured center to center, and the gap between baffles in a row.
  4. Enter a clear margin to keep at the walls.

To run the rows the other way across the room, swap the length and width.

The formula

  • Rows = (ceiling width minus two margins) ÷ row spacing, rounded down, plus one
  • Baffles per row = (ceiling length minus two margins plus one gap) ÷ (baffle length plus gap), rounded down
  • Total baffles = rows × baffles per row
  • Exposed face area = total × baffle length × baffle height × 2, since both faces are exposed

Worked example

Example (fictional). The defaults use the ceiling of the example room, a 40 by 30 ft dining room that is not a Fibson project, with 4 ft long baffles hanging 1 ft, rows 3 ft apart, 1 ft gaps and a 2 ft margin at the walls. (The example room’s own plan uses clouds, not baffles.) The results read:

  • Rows across the width: 9
  • Baffles in each row: 7
  • Total baffles: 63
  • Exposed face area (both sides): 504 sq ft
  • Ceiling area: 1,200 sq ft

The 26 ft between the margins takes rows at 0, 3, 6 and so on up to 24 ft: nine rows. Each row of seven baffles and six gaps is 34 ft long, inside the 36 ft available.

From count to absorption

Face area is not absorption. For flat products, ASTM C423 results come as coefficients summarized as NRC or SAA. For objects such as baffles, the test measures the absorption of each unit in sabins, and that sabins-per-baffle figure is the one to use. Multiply it by the count to get what the layout adds at each frequency.

Working backward is often more useful. The example room needs about 370 sabins added to go from 2.34 s to 1.0 s. Spread over 63 baffles, each would have to contribute about 5.9 sabins at mid frequencies. If the report for the baffle you like shows less, add rows, choose taller baffles or combine them with wall panels; if it shows more, space the rows wider. At a 4 ft row spacing the count drops to 49.

The panel quantity calculator asks for a coefficient rather than sabins per unit. To use it with a per-baffle figure, enter the sabins per baffle as the panel width, 1 as the height, 1.00 as the coefficient and 0 for the covered surface; the panel count it returns is then the number of baffles.

Before you hang anything

  • Sprinklers, lights and air diffusers. Rows have to work around them, and baffles must not block sprinkler spray patterns. Ask the local fire official what clearance applies.
  • Structure. Each baffle hangs on cables or rods fixed to the structure above, which has to suit the load. Ask the landlord or building owner before fixing anything to the deck.
  • Headroom. Over a walking route, the lowest point, hardware included, needs 80 in of clearance under section 307.4 of the 2010 ADA Standards. In an 11 ft room a 1 ft baffle leaves plenty; in a low room it may not. Check with the ADA protrusion checker.
  • Finish class. Ask the building or fire official which interior finish class applies to panels hung in your room, and collect the fire test report for the baffle as built.

Limits

The layout is a grid on an empty rectangle. Real ceilings have beams, ducts, light rows and changes in height that break rows up, so a drawn layout usually holds fewer baffles than this count. The calculator also ignores the baffles’ edges, which add a little absorbing area.

Next steps

See ceiling baffles for sizes and finishes, or ceiling clouds if your ceiling is lower. When you want the layout drawn on your own ceiling plan, around your lights and sprinklers, send it with Plan my room.

Send us the room

Room size, a few photos and what happens in the space. We reply with questions or an outline of the plan.

Plan my room