- You enter
- Room size, decay time now and target, panel data
- You get
- Sabins to add and the number of panels
- Formula
- Sabins to add ÷ net sabins per panel
- Assumes
- One panel type spread around the room
Calculator
Once you know how long a room rings, the next question is how many panels it takes to bring that down. This calculator works backward from a target: it finds the absorption the room has now and at the target, and divides the difference by what one panel adds.
How to use it
- Enter the room’s length, width and ceiling height in feet.
- Enter the reverberation time now, from the reverberation time calculator or a measurement, and the target you want.
- Enter the panel’s width and height in feet and its absorption coefficient. Use a tested coefficient for the frequency band you care about, from a test with the same mounting you plan to use: flat on the wall, on an air gap or hung as a cloud.
- Enter the coefficient of the surface the panel will cover. A panel on painted drywall hides drywall at about 0.05, so it adds 0.80 minus 0.05, not the full 0.80.
The formula
The Sabine formula, rearranged, gives the absorption a room has at any decay time: A = 0.049 × volume ÷ RT60. The calculator uses it twice and then divides:
- Absorption now = 0.049 × volume ÷ reverberation time now
- Absorption at the target = 0.049 × volume ÷ target
- Absorption to add = the difference between the two
- Net absorption per panel = width × height × (panel coefficient minus covered coefficient)
- Panels needed = absorption to add ÷ net absorption per panel, rounded up
It also reports the drop in reverberant sound level, 10 × log10(absorption at the target ÷ absorption now). That is how much the room’s build-up of reflected sound falls, away from any one talker. It does not make the person across the table quieter.
Worked example
Example (fictional). The defaults describe the example room, a 60-seat dining room that is not a Fibson project: 40 by 30 ft with an 11 ft ceiling, about 2.3 seconds now, a target of 1.0 second, and 2 by 4 ft wall panels at an assumed 0.80 covering painted drywall at 0.05. The 0.80 is a planning assumption, not a test result for any product.
- Room volume: 13,200 cu ft
- Absorption now: 281.2 sabins
- Absorption needed at the target: 646.8 sabins
- Absorption to add: 365.6 sabins
- Net absorption per panel: 6.00 sabins
- Panels needed: 61
- Panel face area: 488 sq ft
- Drop in reverberant sound level: 3.6 dB
Why 281.2 and not 276.4. The reverberation time calculator puts this room at 2.34 s from 276.4 sabins. Entering the rounded 2.3 s makes the room look slightly more absorbent than it is. Enter 2.34 and the answer becomes 370.4 sabins to add and 62 panels. Keep the second decimal when you have it.
Why the example room needs less panel
Sixty-one wall panels would cover 488 sq ft, more than a third of the room’s 1,320 sq ft of painted wall. The example room plan reaches about 1.0 s another way, with three groups:
| Group | Face area | Coefficient used | Sabins added |
|---|---|---|---|
| 16 ceiling clouds, 4 by 4 ft | 256 sq ft | 0.90, nothing covered | 230.4 |
| 14 fabric wall panels, 2 by 4 ft | 112 sq ft | 0.80 minus 0.05 = 0.75 | 84.0 |
| 4 printed art panels, 4 by 6 ft | 96 sq ft | 0.80 minus 0.05 = 0.75 | 72.0 |
| Total | 464 sq ft | 386.4 |
That brings the room to 662.8 sabins and 0.98 s, with less face area than the single-type answer. The difference is the clouds. A cloud hangs clear of the ceiling, so the plan does not subtract the drywall above it and counts the full 0.90, while a wall panel adds only its net 0.75. Each square foot of cloud adds more, and the ceiling is the largest hard surface in the room, directly over the tables. Spreading absorption across the ceiling and both long walls also suits the even sound field the Sabine formula assumes.
This calculator handles one panel type at a time. To test a mix, run it once to find the absorption to add, then split that total between panel groups in the surface finish worksheet, one row per group.
Limits
- Spread them out. The arithmetic assumes panels around the room. Thirty panels crowded onto one wall will not do what the numbers say.
- Lab data in a real room. ASTM C423 says lab coefficients “should be used with caution” in real rooms, which are larger than test samples and rarely have an even sound field.
- One band. Run each frequency band separately. Thin panels do much less at low frequencies than at mid frequencies.
- Your target. No code sets one for restaurants. LEED v4.1 lists under 0.6 s for conference rooms and under 0.8 s for hotel meeting or banquet rooms, as reference points.
- Placement rules. Wall panels along a walking route must stay within the ADA protrusion limit; check with the ADA protrusion checker.
Next steps
See what the count looks like on a wall with the wall coverage calculator, or on a ceiling with the baffle layout calculator. For the count, sizes and placement worked out with sourced coefficients, send the room with Plan my room; they come back in the room plan from our acoustic design service.
Send us the room
Room size, a few photos and what happens in the space. We reply with questions or an outline of the plan.