Frequently asked questions
Straight answers about panels, planning, documents and working with us.
Plan my room
- Panels do
- Absorb sound inside a room so it rings less
- Panels do not
- Stop sound passing through walls
- Before you order
- A written room plan and quote
- Our own test reports
- Not yet; we name the makers' reports
These are the questions people ask most before they send us a room. If yours is not here, send it to us with a description of the room and we will answer it.
Sound and panels
Do panels soundproof a room?
No. Acoustic panels absorb sound inside a room, so it rings less and speech is easier to follow. They do not stop sound passing through walls, floors or ceilings. Absorption and sound transmission are measured by different tests (ASTM C423 for absorption; ratings such as STC under ASTM E413 for transmission). If your problem is sound coming through a wall, we will tell you that panels are the wrong tool. The acoustics glossary explains the terms.
How many panels do I need?
It depends on the room’s volume, what its surfaces are made of, how it is used and the reverberation time you want. We work it out from a written estimate instead of a rule of thumb. In our fictional example room, a 60-seat dining room needs 34 panels to go from about 2.3 seconds to about 1 second. You can try your own numbers in the panel quantity calculator.
Planning and ordering
What do you need from me?
Length, width and ceiling height; photos of each wall, the ceiling and the floor; what the surfaces are made of; how the room is used and by how many people; and any constraints such as landlord rules, sprinklers, lighting or a budget range. Our room measurement worksheet lists it all, and what you send and what you receive explains how to photograph a room.
What is a room plan?
The written document you receive before ordering: the reverberation time now, a target with its reasoning, the panel count, sizes and placement drawn on your walls and ceiling, finishes, code and accessibility notes, and the test reports behind every number. A written, itemized quote comes with samples of the shortlisted finishes. How we work walks through each step.
What does a plan cost?
We do not publish prices. Each project is quoted in writing, because the work depends on the room and what the plan involves. Ask when you send us the room and we will answer for your project.
How long does it take?
We do not publish lead times or turnaround times. Timing depends on the room, the panel types and the finishes, and we discuss it with your quote. If you are working toward a date, such as an opening, tell us in your first message.
Do you work outside Wyoming?
We work from measurements and photos, so the room does not need to be near our Casper office. Ask about your location when you send the room.
Panels, art and installation
Can I send you my own art?
Yes, for printed art panels, as long as you own the artwork or have a license to reproduce it. Send the highest-resolution file you have. We cannot print images you do not have the rights to. Colors on a screen differ from print, so you approve a proof before printing.
Do you install?
We do not send our own install crew. Panels arrive labeled for placement, with mounting hardware and a written install guide, and we help you or your installer through the plan. Ceiling clouds and baffles must hang from structure that can carry them and stay clear of sprinklers, lights and air diffusers. See installation support.
Documents and safety
Are your panels fire rated?
Fibson has not yet tested its finished panels, so we do not state a fire class of our own. Your proposal names the core and fabric makers’ ASTM E84 reports, with the indexes and exactly what was tested. A class applies to a panel only when the report covers the assembly as built, and the class your room requires depends on its occupancy. The local building official decides. Materials and safety explains how to read the reports.
What NRC do your panels have?
We do not publish NRC or other absorption ratings for Fibson panels, because we have not tested our finished panels. Plans use the core maker’s published ASTM C423 data, with the edition and the test mounting named, and say so. The NRC calculator shows how NRC and SAA are worked out from a report.
I am an architect or designer. What can you provide?
Samples, spec sheets that cite the source test reports by lab, method, edition and mounting, and draft specification text. We do not have a BIM or CAD library yet. See design trade.
Send us the room