Plain definitions of the terms on data sheets, test reports and room plans.

See the example room
A thick felt book lying open on blank pages with a saffron ribbon bookmark trailing out.
Terms
33 in six groups
Sources
ASTM, ISO, the IBC, GSA and the ADA
Start with
Absorb, Block, Cover

Acoustics borrows its words from physics, building codes and test labs, and data sheets rarely stop to explain them. These are the terms used across this site’s tools and pages, defined plainly. Where a standard or code defines a term, we name it and link the source.

Absorption and how it is rated

Absorption coefficient

The share of sound energy a surface absorbs instead of reflecting, at a given frequency, from 0 (reflects everything) to about 1 (absorbs nearly everything). Our example room assumes 0.05 for painted gypsum board at mid frequencies. Lab results can read above 1.00, because diffraction at the edges of the test sample adds to the measurement, as ASTM C423 explains.

Sabin

A unit of absorption: one square foot of surface that absorbs all the sound reaching it. A surface’s absorption in sabins is its area times its coefficient, so 100 sq ft at 0.50 is 50 sabins. Metric sabins use square meters.

Noise reduction coefficient (NRC)

“The average of the absorption coefficients at 250, 500, 1000 and 2000 hertz, rounded to the nearest multiple .05”, from ASTM C423 (Intertek summary). Handy for quick comparisons, but it hides low-frequency performance. Despite the name, it says nothing about stopping noise passing through a wall. Try it in the NRC calculator.

Sound absorption average (SAA)

“The average of the absorption coefficients at the 1/3 octave band frequencies from 200 to 2500 hertz, rounded to the nearest multiple .01” (same source). It uses twelve bands instead of four, so it is a little more detailed than NRC.

Weighted sound absorption coefficient (alpha-w)

The single-number rating from ISO 11654, common on European and international data sheets. Coefficients are averaged into octave bands, rounded in steps of 0.05 and capped at 1.00, and a reference curve is shifted against them; alpha-w is “the value of the reference curve at 500 Hz after shifting it”. The standard says the rating is not appropriate below 250 Hz. It is not interchangeable with NRC.

Mounting type

How a sample is fixed during an absorption test. ASTM E795 provides the mountings for C423 tests (Intertek summary). Type A is laid directly on the test surface; Type E leaves an air space behind the sample, with the depth in millimeters after the letter (E-400 is 400 mm). The same panel scores differently in different mountings, so a coefficient means little without its mounting type.

ASTM C423

The US test for sound absorption. It “covers the measurement of sound absorption in a reverberation room by measuring decay rate”, for the coefficients of a flat sample and for the absorption of objects such as office screens (ASTM). ASTM’s store lists C423-23e1 as the active edition. The standard itself says its coefficients “should be used with caution” in real rooms.

ASTM E795

The companion standard that sets out how samples are mounted for C423 tests. See mounting type.

ISO 354

The international counterpart of C423. It “specifies a method of measuring the sound absorption coefficient of acoustical materials used as wall or ceiling treatments, or the equivalent sound absorption area of objects” in a reverberation room (ISO).

ISO 11654

The international standard that turns ISO 354 results into practical coefficients and alpha-w, intended for routine applications such as offices, corridors, classrooms and hospitals (ISO).

Reverberation and room sound

Reverberation time (RT60)

The time a sound takes to decay by 60 decibels after its source stops (HyperPhysics). It is the main number in a room estimate. The example room goes from about 2.3 seconds to about 1.0 second.

Sabine formula

The classic estimate of reverberation time from a room’s volume and absorption: RT60 = 0.049 × volume ÷ total absorption, with volume in cubic feet and absorption in sabins (the metric constant is about 0.16). It assumes sound spreads evenly through the room. Try it in the reverberation time calculator.

Eyring formula

A variant of Sabine that works from the average absorption coefficient of all the room’s surfaces. It gives almost the same answer in a hard room and a lower one as absorption rises, so it is often reported beside Sabine for treated rooms.

Flutter echo

A fast, buzzing repeat heard when sound bounces back and forth between two parallel hard surfaces, such as a glass wall facing a drywall wall. One clap in an empty room makes it easy to hear. Absorption on one or both surfaces breaks it up.

Diffusion

Scattering sound in many directions instead of absorbing it or reflecting it in one direction. Diffusers break up strong reflections without removing much sound energy, so on their own they do little to shorten reverberation time.

Bass trap

An absorber built to work at low frequencies, usually thick and often placed in room corners. It exists because thin panels absorb little bass. A plan for a room built around conversation starts with the mid frequencies, as the example room does, and checks the low bands separately.

Quarter-wave rule

A rule of thumb for porous absorbers: a panel absorbs a frequency best when its fibers sit about a quarter of that frequency’s wavelength from the wall behind it, so frequency = speed of sound ÷ (4 × distance). Standing a panel off the wall moves its best range lower. See the air gap calculator.

Sound levels and speech

Decibel (dB)

A logarithmic unit for sound level. Because the scale is logarithmic, levels add by energy: two equal sources make 3 dB more than one, not double. See the decibel addition calculator.

A-weighting (dBA)

A filter applied when measuring sound that reduces the weight of low and very high frequencies, roughly following how the ear responds at moderate levels. Most noise limits and studies use A-weighted levels, written dBA or dB(A), including OSHA’s limits for workers (OSHA 1910.95).

LAeq

The equivalent continuous A-weighted sound level: the steady level that would carry the same sound energy as a changing level over a stated period. Field studies of loud venues report it; the New York City health department measured a median LAeq of 92 dBA across 59 loud venues (Spira-Cohen et al., 2017).

Speech transmission index (STI)

A rating of how intelligibly speech travels from a talker to a listener, from 0 (unintelligible) to 1 (perfectly clear). In open offices, lower is better for concentration: one study found cognitive performance “begins to decrease approximately above STI = 0.21” (Haapakangas et al., 2020).

Lombard effect

“The involuntary tendency of the speaker to increase the vocal effort, while speaking in loud noise” (Bottalico et al., 2022). It is one reason busy dining rooms get louder as they fill: guests talk over the noise, which raises the noise.

Sound masking

An engineered background sound, played through loudspeakers, that makes nearby speech harder to understand. It is the “cover” in Absorb, Block, Cover, and it is designed and tuned by specialists. Acoustic panels do not mask sound.

Absorb, block and cover

Absorb, Block, Cover

The US General Services Administration’s summary of office noise control: “the ABC’s of noise control: Absorb, Block, Cover” (GSA Sound Matters). Absorb with soft surfaces such as panels and acoustic ceilings; block with walls, doors, screens and distance; cover with sound masking. Acoustic panels do the first job only.

Sound transmission class (STC)

A single-number rating of how well a wall, floor, door or window stops airborne sound passing through it, from a lab test to ASTM E90 rated under ASTM E413. It belongs to a different family of tests from absorption, so an NRC tells you nothing about STC. GSA recommends walls of at least STC 53 around video conference rooms.

Ceiling attenuation class (CAC)

A rating of how well a suspended ceiling stops sound traveling from one room to the next through the shared space above, from ASTM E1414 (same E413 source).

Noise isolation class (NIC)

A rating of the sound isolation between two actual rooms, measured on site under ASTM E336 rather than in a lab (same E413 source).

Fire and code

ASTM E84

A comparative surface burning test for exposed surfaces such as walls and ceilings, run with a nominal 24 ft by 20 in specimen in the ceiling position; “flame spread and smoke developed index are reported” (ASTM). ASTM’s store lists E84-26a as the active edition. The building code accepts E84 or UL 723 results.

Flame spread index

The E84 number for how quickly flame travels along the specimen’s surface, on the test’s comparative scale. Lower is better. It sets the interior finish class.

Smoke-developed index

The E84 number for how much smoke the specimen gives off as it burns. All three interior finish classes in the building code require 450 or less.

Interior finish class

The building code’s grouping of E84 results. In the 2021 International Building Code, Class A is a flame spread index of 0 to 25, Class B 26 to 75 and Class C 76 to 200, each with a smoke-developed index of 0 to 450 (2021 Seattle Building Code, chapter 8). The code counts paneling applied for “acoustical correction” as interior finish, and the class a room needs depends on its occupancy and sprinklers. A class applies to a panel only when the test covers the assembly as built, and the local building official decides what a room requires. See materials and safety.

Materials

PET felt

Felt made from polyester (polyethylene terephthalate, the plastic used for drink bottles), often with recycled content, pressed into panels, tiles and cut shapes. Thin felt absorbs mostly mid and high frequencies. Recycled-content figures should come from the felt maker’s documents; for context, the US EPA puts the 2018 recycling rate of PET bottles and jars at 29.1 percent (EPA). See felt panels.

Acoustically transparent fabric

A fabric open enough for sound to pass through it into the absorbent core behind. Fabric-wrapped and printed art panels depend on it, since a tight or coated fabric reflects sound before the core can absorb it. A printed fabric has to stay acoustically transparent after printing, and its fire report has to cover it as printed. See printed art panels.