Decibel addition calculator
Combine several sound levels into one, the way sound energy actually adds.
Plan my room
- You enter
- Two to four levels in decibels
- You get
- The combined level and its rise over the loudest
- Formula
- 10 × log10 of the summed sound energy
- Rule of thumb
- Two equal sources make 3 dB more than one
Calculator
Decibels do not add like ordinary numbers. Two people talking at 70 dB do not make 140 dB; together they make about 73. The decibel is a logarithmic scale, so levels have to be turned back into sound energy, added, and converted again. This calculator does that for up to four sources.
How to use it
Enter at least two levels in decibels, one per source: a conversation, the background music, the espresso machine, the ventilation. Leave sources 3 and 4 blank if you only have two. Use levels taken with the same weighting, usually A-weighted (dBA), and measured at the same spot, such as a typical seat or desk.
The formula
combined level = 10 × log10(10^(L1 ÷ 10) + 10^(L2 ÷ 10) + …)
A few results are worth remembering:
- Two equal sources make 3 dB more than one.
- A source 10 dB quieter than another adds less than half a decibel.
- Four equal sources make 6 dB more than one; ten make 10 dB more.
That is why the loudest source usually sets the total, and why turning down a quiet one changes little.
Worked example: a restaurant
Example (fictional). At one table in a busy dining room, the two neighboring tables talk at 70 dB each, background music reaches 65 dB and the kitchen and ventilation add 60 dB. The results read:
- Sources combined: 4
- Combined level: 73.8 dB
- Above the loudest single source: 3.8 dB
Turning the music down 10 dB, to 55, brings the total to 73.3 dB. Switching it off gives 73.2 dB. The neighboring tables set the level.
Field studies point the same way. Hodgson and colleagues measured 45 to 82 dBA in ten eating establishments. In Hong Kong, To and Chung recorded peak-hour levels of 66.7 to 82.6 dBA and found they “depended on the levels of occupancy density only”. In a full room the guests are the main source, and they raise their voices as it gets louder: Bottalico and colleagues describe this Lombard effect as “the involuntary tendency of the speaker to increase the vocal effort, while speaking in loud noise”. Their 2022 study of adults over 60 found that background noise below 50 dBA lets older diners keep their vocal effort low and their “willingness to spend time and money high”.
Worked example: an office
Example (fictional). At a desk in an open office, ventilation runs at 45 dB and two colleagues nearby are each on a call at 60 dB. Enter 45, 60 and 60: the combined level is 63.1 dB, against 63.0 dB for the two calls alone. The ventilation hardly registers; the calls decide what the desk hears.
Where panels fit in
Absorption does not turn a talker down. What it lowers is the reverberant sound, the reflected build-up that fills a room away from any one source. The drop is 10 × log10(absorption after ÷ absorption before). In the example room, going from 276.4 to 662.8 sabins lowers the reverberant level by about 3.8 dB and shortens the decay from about 2.3 to about 1.0 second, so each word clears sooner. The panel quantity calculator reports this drop for any plan.
OSHA is about hearing, not comfort
OSHA’s noise standard, 29 CFR 1910.95, protects workers’ hearing. It sets a permissible exposure of 90 dBA over 8 hours and requires a hearing conservation program at an 8-hour time-weighted average of 85 dBA. It sets no target for whether guests can talk or whether an office is comfortable to work in, so a dining room can be well within the OSHA limits and still too loud for conversation. At the loud end, the New York City health department measured a median LAeq of 92 dBA across 59 loud venues; if your staff work shifts in a room like that, the OSHA rules deserve a look in their own right.
Limits
- Phone meter apps are fine for comparing before and after at the same spot. They are not calibrated instruments.
- The calculator adds steady levels. It does not average a level that changes over time; that is what an LAeq measurement does.
- Levels depend on position. A source that reads 70 dB at one seat reads differently across the room.
Next steps
Note where your noise comes from with the restaurant acoustics checklist or the open office acoustics checklist. The acoustics glossary explains dBA, LAeq and the rest. When you want a plan for the room, send it with Plan my room.
Send us the room
Room size, a few photos and what happens in the space. We reply with questions or an outline of the plan.