Fibson homePlan my room
Menu

Open office acoustics checklist

Eighteen checks for an open office where calls and chatter carry.

Plan my room
A row of tall felt snake plants in matching planters standing like a low divider.
Items
18 in five groups
Framework
GSA's Absorb, Block, Cover
Panels do
The absorbing; blocking and masking are separate
Then
Send the floor plan with Plan my room

Checklist

Tick items as you confirm them. Progress stays on this page only; download or print the list when you are done.

What people complain about
The room
Absorb, block and cover
People and policy
Before you order

0 of 18 items confirmed

Open offices are rarely loud the way restaurants are. The trouble is speech: a call two desks away that you can follow word for word. The US General Services Administration’s guide Sound Matters calls acoustic problems “a leading source of employee dissatisfaction in offices”, and in its baseline survey “60% said they could get more done if it were quieter”. This checklist helps you pin down what people actually hear and which kind of fix fits.

How to use it

Tick items as you confirm them. The list stays on this page and nothing is sent. Download the CSV or print it for the facilities file, or send it with Plan my room.

What people complain about

Start with the complaints, because they tell you which problem you have. Calls carrying across the floor and conversations you can follow from three desks away point to speech that is too intelligible. A room that sounds loud even when few people are talking points to reverberation off hard ceilings and walls. Nowhere to take a private call is a layout and policy problem that panels will not solve.

Research backs the focus on speech. Haapakangas, Hongisto and Liebl found in 2020 that cognitive performance “begins to decrease approximately above STI = 0.21”, with the largest drop reached at STI 0.44. STI, the speech transmission index, rates how intelligible speech is on a scale from 0 to 1. And in two field studies, Bernstein and Turban found that after moves to open offices, face-to-face interaction “decreased significantly (approx. 70%)”.

The room

Record the ceiling type and height, and mark glass walls, columns and hard partitions on a plan. Mark desk clusters, collaboration zones and quiet zones. Note how loud the HVAC is: a very quiet room can make speech more distracting, because nothing covers it.

Absorb, block and cover

GSA frames office noise control as “the ABC’s of noise control: Absorb, Block, Cover”. Panels do only the first.

  • Absorb. Plan ceiling absorption first where the ceiling is hard; GSA recommends ceilings with a minimum NRC of 0.9 in open-plan areas. Under an open deck, ceiling baffles or clouds do this job. Then add wall panels on hard walls that face desk clusters.
  • Block. Screens, storage and furniture between talkers and listeners interrupt the direct path of speech. Panels on a wall do not.
  • Cover. Sound masking adds a steady, engineered background sound that makes nearby speech harder to follow. It is a separate system, best planned with a specialist if speech privacy is the goal. Fibson does not design or sell masking.

For reverberation, LEED v4.1 lists under 0.8 s for open-plan offices without masking, at 500, 1,000 and 2,000 Hz, and the legacy WELL v1 standard set 0.5 s for open offices. The reverberation time calculator shows where your floor stands.

People and policy

Panels will not fix a team with nowhere to take a call. Give phone and video calls a room or booth to move to, keep loud collaboration areas apart from focus areas, and agree on headset use and call etiquette with the team.

Before you order

Collect fire and absorption test reports for each material, get the mounting method approved by the landlord or facilities team, and check colors and finishes against the office palette. In the 2021 International Building Code, business occupancies (Group B) need Class C interior finish in rooms and enclosed spaces; your local building official decides which edition applies and what each area of the floor needs. The acoustic panel spec checklist lists the documents to ask any supplier for.

Example (fictional). Maple Row Studio (fictional) is a 14-person design office with an exposed concrete deck 13 ft up, a polished concrete floor and a glass wall to the street. People complain that calls carry and that noise builds through the afternoon. Working through the checklist points to ceiling absorption first, with baffles between the light rows, then wall panels on the one long drywall wall facing the desks, a booth for calls and an agreed headset rule, with masking left as a separate question for a specialist.

Next steps

See offices for how we plan workplaces and the meeting room acoustics checklist for the rooms around the floor. Send the floor plan and photos with Plan my room.

Send us the room

Room size, a few photos and what happens in the space. We reply with questions or an outline of the plan.

Plan my room