Example room: a 60-seat dining room

A fictional dining room, worked from 2.3 seconds of echo to about 1 second.

Plan my room
A round felt pebble drops into a calm oat-colored pond seen from above, with three soft rings spreading and fading into a flat surface.
Room
40 by 30 ft, 11 ft ceiling, 60 seats (fictional)
Now
About 2.3 seconds at mid frequencies
Plan
16 clouds, 14 wall panels, 4 printed art panels
After
About 1.0 second, estimated
Long-wall elevation of the example dining roomA 40-foot wall with an 11-foot ceiling. Ceiling clouds hang below the ceiling over the tables, seven fabric wall panels sit at seated ear height and two printed art panels hang near each end.
Fictional example. One long wall shown; the other mirrors it.
Panel groups
Bare room
2.3 s
With the panels ticked
1.0 s

A Sabine estimate with assumed coefficients, not a measurement. The worked example

Example (fictional). Not a Fibson project. The room, its finishes and every coefficient on this page are invented to show how a room plan is worked out. The coefficients are planning assumptions, not test results.

The elevation above lets you hang and remove the three panel groups and watch the estimate change. This page shows the arithmetic behind it, in the same order a real room plan follows: the room, its surfaces, the estimate now, the target, the panels, the estimate after, and the notes and limits that go with them.

The room

A 60-seat dining room, 40 by 30 ft with an 11 ft ceiling, so its volume is 40 × 30 × 11 = 13,200 cu ft. The floor is sealed wood, the walls and ceiling are painted gypsum board, and the front has 220 sq ft of storefront glass. There are tables, chairs and a bar, and nothing else soft. The estimate is for the room furnished and unoccupied, at mid frequencies (500 to 1,000 Hz).

Surfaces and absorption

Each surface absorbs a fraction of the sound that hits it, its absorption coefficient. Area times coefficient gives absorption in sabins (square feet of perfect absorption).

Surface Area (sq ft) Coefficient Sabins
Floor, sealed wood 1,200 0.07 84.0
Ceiling, painted gypsum board 1,200 0.05 60.0
Storefront glass 220 0.12 26.4
Walls, painted gypsum board 1,320 0.05 66.0
Tables, chairs and bar (allowance) 40.0
Total 276.4

The wall area is the perimeter, 140 ft, times the 11 ft height, which is 1,540 sq ft, less the 220 sq ft of glass. Nearly 4,000 sq ft of hard surface adds up to fewer than 280 sabins. That is the problem in one line.

The formula and the arithmetic

The Sabine formula, in feet, reads:

RT60 = 0.049 × V ÷ A

where V is the volume in cubic feet and A is the total absorption in sabins. For this room:

  • 0.049 × 13,200 = 646.8
  • 646.8 ÷ 276.4 = 2.34 seconds, about 2.3 s

A sound in this room takes more than two seconds to fade by 60 decibels. With 60 people talking, every sentence lands on the tail of the ones before it, everyone talks a little louder, and the room gets louder still.

The target and why

We set a target of about 1 second. No building code sets a reverberation target for restaurants, so this is a planning choice, not a requirement. It is less than half the present time, which should make conversation at a table much easier, while leaving the room some liveliness. For reference, LEED v4.1 lists under 0.8 s for hotel meeting or banquet rooms (and under 0.6 s for conference rooms). We stayed a little above the banquet figure because the estimate is for an empty room, and a full room absorbs more.

Reaching 1 second needs about 646.8 sabins in total (646.8 ÷ 1.0), so roughly 370 more than the room has.

The panel plan

Group Size Count Area (sq ft) Assumed coefficient Net sabins
Ceiling clouds 4 by 4 ft 16 256 0.90 230.4
Fabric wall panels 2 by 4 ft 14 112 0.80, net 0.75 84.0
Printed art panels 4 by 6 ft 4 96 0.80, net 0.75 72.0
Total added 34 464 386.4

The ceiling clouds hang in four rows of four over the tables. They cover nothing, so they add their full assumed value. The 14 fabric wall panels sit at seated ear height, seven on each long wall, and the four printed art panels hang two on each long wall. Wall panels cover gypsum board that was already absorbing 0.05, so each square foot adds 0.80 minus 0.05, or 0.75.

In a real plan each coefficient would come from a published ASTM C423 report for the core, tested in a mounting that matches how the panel is hung: a suspended mounting for the clouds, a wall mounting for the others. See materials and safety.

The result

  • 276.4 + 386.4 = 662.8 sabins
  • 646.8 ÷ 662.8 = 0.98 seconds, about 1.0 s

Each group on its own

Panels hung Estimated RT60
None 2.34 s
Clouds only 1.28 s
Wall panels only 1.79 s
Art panels only 1.86 s
Clouds and wall panels 1.09 s
Clouds and art panels 1.12 s
Wall panels and art panels 1.50 s
All three groups 0.98 s

The clouds do the most work because they are the largest area at the highest coefficient, over the largest untreated surface. No single group reaches the target, and the wall groups without the clouds stop at 1.5 seconds. If a project had to be done in stages, the clouds would come first.

Coverage

The clouds cover 256 sq ft, about 21 percent of the 1,200 sq ft ceiling. The wall and art panels together cover 208 sq ft: about 24 percent of the two long walls (880 sq ft) and about 16 percent of all the painted wall. Spreading panels across the ceiling and both long walls, rather than piling them onto one surface, keeps the room closer to the even sound field the formula assumes.

Accessibility notes

  • Protrusion (ADA 307.2). Objects with leading edges more than 27 in and not more than 80 in above the floor may protrude no more than 4 in into a circulation path. The wall panels in this plan, fabric and printed, project about 2.5 in with their mounting, within that limit. The ADA protrusion checker runs the same check.
  • Headroom (ADA 307.4). Vertical clearance must be at least 80 in. The clouds hang with at least 80 in clear beneath them.

Interior finish note

The International Building Code treats panels applied for acoustical correction as interior finish (IBC 806.2), and Table 803.13 sets the required flame spread class by occupancy, location and sprinklers. In the 2021 model text, as published in the Seattle Building Code, footnote e to that table permits Class C finish in rooms of places of assembly with an occupant load of 300 persons or less. Our judgement: the plan would still default to materials with documented Class A reports, because local adoptions and amendments vary. The occupancy and occupant load of a real room come from the code analysis for that building, and the local building official decides. A class applies to a panel only when the report covers the assembly as built.

Limits of the estimate

  • It assumes an even sound field. Sabine treats sound as spread evenly through the room. Real rooms rarely behave that way, and ASTM C423 itself says laboratory coefficients “should be used with caution” in real rooms.
  • Occupied rooms ring less. People and clothing absorb sound, so a full Friday night will read lower than 0.98 s. That is why the target is set for the empty room.
  • It covers mid frequencies only. Bass behaves differently, and thin panels absorb less of it.
  • The coefficients are assumed. Lab coefficients can even exceed 1.00 because of edge effects (C423 section 5.3), which is one more reason to read the report, not just the headline number.
  • It is about echo, not noise from elsewhere. Kitchen noise, HVAC and sound through walls need other measures; panels absorb sound inside the room and do not stop it passing through walls.

Try the same numbers yourself in the reverberation time calculator and the panel quantity calculator, which start with this room as their example.

Example (fictional). Not a Fibson project. All numbers on this page are illustrative. A real room plan uses your measurements, published test data and the notes your room needs.