Fibson homePlan my room
Menu

Ceiling baffles

Vertical blades hung in rows, for high, open or crowded ceilings.

Plan my room
Long flat sheets of oat and saffron felt pasta hanging in a neat row over a wooden drying rack.
Hangs
Edge down in parallel rows
Suits
High ceilings and open decks with ducts and pipes
Rated in
Sabins per baffle from an object test
Plan it with
The baffle layout calculator

A baffle is an acoustic panel turned on its edge. Instead of lying flat under the ceiling like a cloud, it hangs vertically, long side down, in parallel rows. Both faces and the bottom edge are open to the room, and the rows leave the ceiling between them clear for lights, sprinklers and ducts. In a cafe with an exposed deck, a taproom in an old warehouse or an open office with services overhead, baffles are often the easiest way to put a lot of absorption where the sound collects.

How it is built

A baffle is either a rigid absorptive core (mineral wool, fiberglass or PET) wrapped in acoustically transparent fabric, or a solid blade of PET felt. Hanging points along the top edge let it hang straight and level from the structure above. Felt baffles can also be cut to curved or stepped profiles, so a row reads as a wave, or as a line that follows the bar, rather than a set of rectangles.

Where baffles work best

  • High and open ceilings. Where the ceiling is far above the room or open to the deck, rows of baffles bring absorption down toward the people without a large flat surface to support.
  • Crowded ceilings. Rows run between sprinkler lines, light tracks and ducts instead of covering them.
  • Long rooms. Rows can follow the length of a bar, a counter or a run of desks and give the ceiling a clear direction.
  • Rooms that want the look. Rows of color overhead are a design element in their own right, and they can change color from zone to zone.

Where they do not

  • Low ceilings. A baffle hangs down by its own depth, and over a walking route its bottom edge must stay at least 80 in above the floor (ADA 307.4). Under a low ceiling that leaves little room, and flat ceiling clouds usually suit better.
  • Small rooms. In a small meeting room or home office, a few wall panels or a single cloud is usually simpler.
  • Echo between two walls. Flutter between parallel walls needs wall panels.
  • Sound through walls and floors. Baffles absorb sound inside the room. They do not stop it reaching the next room or the floor above.

Why baffles are rated in sabins per baffle

NRC and SAA are single numbers reported for products with extended flat surfaces, such as wall panels laid over a test area. A baffle is not a flat surface: it hangs in open air with two faces and an edge exposed. ASTM C423 covers this case by measuring the absorption of an object rather than a coefficient, and the result is given in sabins per baffle at each frequency band. To estimate a plan, multiply the per-baffle figure by the number of baffles, band by band, and add it to the room’s existing absorption. Baffles hung close together partly shade one another, so the number of baffles and the spacing used in the test matter, and the plan keeps close to that spacing or says where it does not.

The baffle layout calculator counts how many baffles fit a ceiling at a given row spacing. The panel quantity calculator works out how much absorption a target decay time needs.

Sizes and options

Baffles are made to the plan: length, depth, thickness, profile, color and the height each row hangs at, with every row drawn on a ceiling plan around your services. There is no fixed catalog of sizes. Rows can run in one direction or change direction between zones, and colors can vary row by row. You approve samples before anything is made, as described under custom fabrication.

How absorption and fire are documented

Fibson has not yet tested its finished baffles. Your proposal names the source for every per-baffle figure: the maker and product, its size and construction, tested to ASTM C423 (with the edition) as a suspended object, the number of baffles and their spacing in the test, the lab, and the report number and date. If a source publishes only an NRC for flat panels of the same material, we say so and do not convert it into a per-baffle figure. Installed results vary with room shape, furnishings, occupancy and spacing.

For fire, the proposal gives the ASTM E84 class, the flame spread and smoke-developed indices, the edition and exactly what was tested. A class applies to your baffles only where the report covers the baffle as built: the core, facing and adhesive, or the felt itself. E84 notes that supporting materials can change results, so a report on a different construction does not carry over.

Installation and code notes

  • Structure and hanging. Hang baffles from structure suited to the load, never from sprinkler pipes, ducts, conduit or light fixtures. On an open deck, the plan shows where each hanging point goes.
  • Sprinklers and lights. Baffles can interfere with sprinkler spray and throw shadows from lights. The ceiling plan marks every head, light, detector and diffuser, and positions should be confirmed with your fire sprinkler contractor or local fire official.
  • Clearance. At least 80 in from the floor to the bottom edge over walking routes (ADA 307.4).
  • Interior finish and stability. Baffles are interior finish under the IBC (806.2), and the suspension must keep them attached at room temperatures of 200°F for at least 30 minutes (803.14). The local building official decides what applies.

Installation support provides the hardware, a dimensioned ceiling plan and a walk-through with your installer.

Care and cleaning

Dust baffles occasionally with a soft vacuum brush, working along each row. In a cafe with an open kitchen, keep rows out of the air directly above the cooking line, where grease settles. Follow the fabric or felt maker’s instructions for spots.

Example (fictional). A taproom with a 40 by 30 ft ceiling open to the deck wants rows of felt baffles, 4 ft long and 1 ft deep. With rows 3 ft apart center to center, 1 ft gaps between baffles and a 2 ft clear margin at the walls, the baffle layout calculator fits 9 rows of 7, or 63 baffles, with 504 sq ft of exposed face counting both sides. If the felt maker’s report gave, say, 5 sabins per baffle at 500 Hz (a number made up for this example, not a Fibson figure), 63 baffles would add about 315 sabins at that band, and the plan would repeat the sum for every band. This is not a Fibson project.

Send us the room

Room size, a few photos and what happens in the space. We reply with questions or an outline of the plan.

Plan my room