Acoustic panel specification checklist

The documents to ask any panel supplier for before you order.

Request samples and spec sheets
A felt magnifying glass held over a woven fabric swatch, its lens showing enlarged loose fibers.
Items
16 in four groups
Absorption
ASTM C423 report with the E795 mounting named
Fire
ASTM E84 indexes and the class they meet
Applies to
Any supplier, including us

Checklist

Tick items as you confirm them. Progress stays on this page only; download or print the list when you are done.

Absorption data
Fire and safety
Materials and indoor air
Order and delivery

0 of 16 items confirmed

Two panels can look the same and perform very differently, and a data sheet can be accurate and still not describe the panel you are buying. This checklist lists the documents and answers to ask any supplier for, us included, before you approve an order. It is written with specifiers in mind, and an owner can use it just as well.

How to use it

Tick items as each document arrives. The list stays on this page and nothing is sent. Download the CSV or print it to attach to a submittal log or a quote comparison.

Absorption data

Ask for a test report to ASTM C423 for the exact construction offered: the same core, thickness and facing. ASTM’s store lists C423-23e1 as the active edition, and older reports are common, so note which edition each report used.

The report should name the mounting from ASTM E795, because mounting changes the numbers. Type A is laid directly on the test surface; Type E leaves an air space, with its depth in millimeters after the letter, as in E-400. A wall panel tested flat and a cloud tested suspended are not comparable.

Ask for the coefficient in every frequency band, not only the NRC. NRC averages four bands and rounds to the nearest 0.05, and it can hide a panel that does little in the low bands; the NRC calculator shows how. For baffles and other objects, ask for absorption per unit in sabins. Note the lab’s name and the test date. And keep in mind that C423 itself says its coefficients “should be used with caution” in real rooms, which are larger than the test sample and rarely have an even sound field.

Fire and safety

Ask for a surface burning test to ASTM E84, which reports a flame spread index and a smoke-developed index; ASTM’s store lists E84-26a as the active edition. The building code turns those indexes into interior finish classes. In the 2021 International Building Code, section 803.1.2:

Class Flame spread index Smoke-developed index
A 0 to 25 0 to 450
B 26 to 75 0 to 450
C 76 to 200 0 to 450

The code also treats materials that meet the NFPA 286 acceptance criteria as complying with Class A.

Then ask exactly what was tested. ASTM E84 warns that materials supporting the specimen can lower its flame spread index, and that results “do not necessarily relate” to unsupported specimens. A core’s report does not automatically cover the core with fabric and adhesive on it, and a printed fabric needs a report that covers it as printed. A class applies to a panel only when the report covers the assembly as built.

Ask too for mounting hardware rated for the panel’s weight and for the wall or ceiling it goes on. The IBC requires interior finish to be fastened so it “will not readily become detached where subjected to room temperatures of 200°F (93°C) for not less than 30 minutes” (section 803.14). Which class your room needs depends on its occupancy, its sprinklers and the code edition in force; the local building official decides.

Materials and indoor air

Ask the supplier to name the core (for example mineral wool, fiberglass or PET felt) and the fabric or facing, with its cleaning code. Where the project calls for emissions testing, ask for results under the California Department of Public Health Standard Method. Version 1.3, published in June 2026, brings new emission criteria into effect on January 1, 2027, so check which version a report used.

For fabrics, California’s AB 1817 lowers the PFAS threshold for textile articles, a term that includes furnishings and upholstery, from 100 ppm to 50 ppm total organic fluorine on January 1, 2027. Whether a particular acoustic fabric counts as a textile article is a legal question, so ask each fabric supplier for a dated PFAS statement. If recycled content is claimed, ask for the document it comes from.

Order and delivery

Confirm sizes, edge details and colors in writing, approve samples or swatches before production, and make sure installation instructions, hardware and care instructions come with the panels.

How we answer this list

Fibson has not yet tested its finished panels. Our proposals name the core or fabric maker’s published report behind every absorption and fire figure we use: the product, the test method and edition, the lab, the report date and the mounting type. Where a report covers only the core, we say so, and we do not describe the finished panel with a fire class its report does not cover. Installed results vary with room shape, furnishings, occupancy and mounting. Materials and safety explains how we cite reports, and architects and designers can request samples and spec sheets through design trade.