Fibson homePlan my room
Menu

NRC and SAA calculator

Work out NRC and SAA from a lab report and see what they leave out.

See how we cite test data
An old-fashioned balance scale with a fluffy heather felt block on one pan and small round brass weights on the other.
You enter
Twelve third-octave coefficients from a report
You get
NRC to 0.05, SAA to 0.01 and the weakest band
Standard
ASTM C423 with the mounting named per ASTM E795
Compare
Only products tested in the same mounting

Calculator

The example values describe a fictional 60-seat dining room. Replace them with your own; results update as you type. Nothing you enter leaves your browser.

Results

Average at 250, 500, 1,000 and 2,000 Hz
0.7750
NRC (rounded to the nearest 0.05)
0.80
Average of the twelve bands, 200 to 2,500 Hz
0.7708
SAA (rounded to the nearest 0.01)
0.77
Lowest band entered
0.20 at 200 Hz

Coefficients above 1.00 are normal in reports because of edge effects in the test. Compare two products only when they were tested with the same mounting type (for example Type A, flat on the test surface).

NRC, the noise reduction coefficient, is the number most acoustic panel data sheets lead with. It is handy for a quick comparison and easy to misread. This calculator takes the absorption coefficients from a test report and works out NRC and SAA, the sound absorption average, each with its own rounding rule, and points out the weakest band so you can see what the single number hides.

How to use it

Find the table of sound absorption coefficients in the lab report. US reports test to ASTM C423 and list a coefficient for each third-octave band. Copy the twelve values from 200 to 2,500 Hz into the fields exactly as printed, including any above 1.00. Results update as you type.

The formulas

Both ratings come from ASTM C423. As the accredited test lab Intertek summarizes them:

  • NRC is “the average of the absorption coefficients at 250, 500, 1000 and 2000 hertz, rounded to the nearest multiple .05”.
  • SAA is “the average of the absorption coefficients at the 1/3 octave band frequencies from 200 to 2500 hertz, rounded to the nearest multiple .01”.

NRC uses four bands and coarse rounding; SAA uses all twelve bands between 200 and 2,500 Hz and finer rounding. Both are reported for products with flat, extended surfaces. For objects such as baffles, C423 measures the absorption of each unit in sabins instead.

Worked example

Example (fictional). The default values are a fictional sample report, not test data for any real product or for any Fibson panel: 0.20, 0.30, 0.42, 0.58, 0.75, 0.88, 0.98, 1.03, 1.05, 1.04, 1.02 and 1.00 for the bands from 200 to 2,500 Hz. The results read:

  • Average at 250, 500, 1,000 and 2,000 Hz: (0.30 + 0.75 + 1.03 + 1.02) ÷ 4 = 0.7750
  • NRC, rounded to the nearest 0.05: 0.80
  • Average of the twelve bands, 200 to 2,500 Hz: 9.25 ÷ 12 = 0.7708
  • SAA, rounded to the nearest 0.01: 0.77
  • Lowest band entered: 0.20 at 200 Hz

Two things stand out. First, this sample sits exactly halfway between 0.75 and 0.80, and the calculator rounds a half up; if a report prints a different NRC for the same coefficients, go by the report and ask the lab. Second, an NRC of 0.80 sounds like a panel that soaks up 80 percent of everything, yet at 200 Hz this one absorbs 0.20. Thin porous panels are strong at mid and high frequencies and weak in the bass, and NRC averages that away.

Why coefficients go above 1.00

A surface cannot absorb more sound than reaches it, yet test results often exceed 1.00. ASTM C423 explains that diffraction at the edges of the test sample can push measured coefficients above unity. It is normal and not a sign of a faulty report. Copy the values as printed.

Mounting changes the numbers

ASTM E795 provides the mounting methods for C423 tests, and the report has to name the one used, because it changes the result. Type A is laid directly against the test surface, like a panel fixed flat to a wall. Type E leaves an air space behind the sample, and the number after the letter is its depth in millimeters: E-400 means 400 mm, about 16 in. The same panel can score very differently in the two. Compare NRCs only when the mounting types match, and use data from the mounting you will actually install. The air gap calculator shows why depth matters.

Alpha-w on international data sheets

European and international data sheets often quote alpha-w, the weighted sound absorption coefficient from ISO 11654, instead of NRC. It is built differently. ISO 354 is the international counterpart of the C423 test; ISO 11654 averages its results into octave bands, “rounded in steps of 0,05” and capped at 1.00, then shifts a reference curve against them. Alpha-w is “the value of the reference curve at 500 Hz after shifting it”, and the standard says the rating “is not appropriate below” 250 Hz. Alpha-w and NRC are not interchangeable, and this calculator does not compute alpha-w. Ask for the frequency table behind either rating.

What a single number is good for

Guidance documents use NRC as a floor. The US General Services Administration’s Sound Matters recommends ceilings of at least NRC 0.9 in open-plan offices and NRC 0.8 in meeting rooms, and wall panels of at least NRC 0.8 in conference, meeting and training rooms. ISO 11654 describes its own single number as meant for routine applications such as offices, corridors, classrooms and hospitals. For a room plan, the full table is what matters: it shows whether a panel helps with the low end of a busy dining room or only with the top.

Fibson and test data

Fibson has not yet tested its finished panels. When we plan a room, the proposal names the core or fabric maker’s published report behind every coefficient we use: the product, the test method and edition, the lab and the mounting type. Materials and safety explains how we cite reports, and the acoustic panel spec checklist lists what to ask any supplier for. Specifiers can request samples and spec sheets through design trade.

Send us the room

Room size, a few photos and what happens in the space. We reply with questions or an outline of the plan.

Plan my room