Air gap calculator
How spacing a panel off the wall shifts the frequencies it absorbs best.
See installation support
- You enter
- Panel thickness, air gap and speed of sound
- You get
- Quarter-wave frequency at the face and middle
- Rule
- Speed of sound ÷ (4 × distance from the wall)
- Real answer
- Tested coefficients for that mounting depth
Calculator
A porous panel, such as a fabric-wrapped fiberglass or mineral wool core or a thick PET felt panel, absorbs sound by making air move through its fibers. Right at a hard wall the air hardly moves, because the wall stops it. A little way out it moves a lot. Standing a panel off the wall puts its fibers where the air is moving more, especially at lower frequencies. This calculator estimates where that happens.
How to use it
- Enter the panel thickness in inches.
- Enter the air gap between the wall and the back of the panel. Enter 0 for a panel fixed flat.
- Leave the speed of sound at 1,125 ft per second unless you have a reason to change it; that is about right for room-temperature air.
The rule of thumb
When sound reflects off a hard wall, the air is still at the wall and moves fastest a quarter of a wavelength away from it. A porous panel works best on a frequency when its fibers sit near that point. The frequency whose quarter wavelength matches a given distance from the wall is:
frequency = speed of sound ÷ (4 × distance from the wall)
with the distance in feet. The calculator gives the answer twice: at the panel’s face (thickness plus gap) and at the middle of the panel (half the thickness plus gap).
Worked example
Example (fictional). A 2 in panel on a 2 in air gap, with sound traveling at 1,125 ft per second:
- Distance from wall to panel face: 4.00 in
- Quarter-wave frequency at the face: 844 Hz
- Quarter-wave frequency at the middle of the panel: 1,125 Hz
At 844 Hz one wavelength is 16 in, and a quarter of it is the 4 in from the wall to the panel’s face.
Changing the gap shows the trend. With the same 2 in panel:
| Air gap | Wall to face | At the face | At the middle |
|---|---|---|---|
| 0 in (flat) | 2.00 in | 1,688 Hz | 3,375 Hz |
| 1 in | 3.00 in | 1,125 Hz | 1,688 Hz |
| 2 in | 4.00 in | 844 Hz | 1,125 Hz |
| 4 in | 6.00 in | 563 Hz | 675 Hz |
Doubling the distance halves the frequency.
How to read the result
Read the numbers as a direction, not a cutoff. The panel still absorbs below these frequencies, just less, and above them it is usually doing well. What the rule tells you is that a deeper mounting, or a thicker panel, moves the panel’s useful range lower, toward the low end of voices and the rumble of a full room.
The tested coefficients are the real answer
The quarter-wave rule squeezes the physics into one line. The answer that counts is the panel’s tested coefficients at the mounting depth you will actually use. ASTM E795 provides the mountings for C423 absorption tests: Type A is flat against the test surface, and Type E leaves an air space whose depth in millimeters follows the letter, so E-400 is 400 mm, about 16 in. Before you compare a supplier’s data with your plan, check that the mounting matches. The NRC calculator explains the ratings, and the acoustic panel spec checklist lists what to ask for.
Ceiling clouds are the extreme case: a cloud hung below the ceiling has a deep air space behind it. Its data has to come from a test that suspends it the same way, not from a flat-mounted test.
Watch the projection
A deeper gap makes a deeper panel. A 2 in panel on a 2 in gap already sits 4 in out from the wall before any hardware. Under section 307.2 of the 2010 ADA Standards, objects on a walking route with a leading edge more than 27 in and not more than 80 in above the floor may protrude no more than 4 in. Check any spaced-off wall panel with the ADA protrusion checker, and keep deep mountings above 80 in or where people do not walk past.
Next steps
If you are choosing between a flat mount and a spaced mount, ask the supplier for coefficients in both. Cleats, standoffs and spacing are covered in installation support, and fabric-wrapped wall panels covers the core options. When you send us the room, the room plan names the mounting for each panel group and the test report behind its numbers.