Fibson homePlan my room
Menu

Surface finish worksheet

List every surface, its area and coefficient, and total the absorption.

Plan my room
Four felt material samples, brick, wood grain, glass and carpet, laid side by side with a paint chip fan beside them.
You enter
Room volume, then each surface, area and coefficient
You get
Sabins per row, total absorption and Sabine RT60
Good for
Testing panel groups before anything is ordered
Output
A CSV file or a printed sheet

Worksheet

The rows describe a fictional 60-seat dining room. Edit them, add your own surfaces and download the result as CSV. Nothing leaves your browser.

SurfaceMaterialArea (sq ft)Coefficient (500 to 1,000 Hz)SabinsRemove
84.0
60.0
26.4
66.0
40.0

Results

Surface area entered
3,980 sq ft
Total absorption
276.4 sabins
Reverberation time (Sabine)
2.34 s

The reverberation time calculator treats a room as a floor, a ceiling, four walls and some glass. Real rooms are rarely that tidy: one brick wall, a carpeted lounge corner, a glass partition, a tiled bar front. This worksheet lets you list every surface separately, with its own area and coefficient, and totals the absorption and the reverberation time as you go. It is the same surface inventory that sits at the center of our room estimate.

How to use it

  1. Enter the room volume in cubic feet: length × width × average ceiling height.
  2. Edit the rows: one per surface, with a short name, the material, the area in square feet and its absorption coefficient for 500 to 1,000 Hz. The sabins column fills in as you type.
  3. Use Add a surface for anything else, and Remove for rows you do not need.
  4. Download CSV or Print to keep the sheet or send it with Plan my room. The CSV includes the room volume and each row’s sabins.

Getting areas and coefficients right

  • Subtract openings. Take windows, glass doors and tiled areas out of the wall area and give each its own row, so nothing is counted twice.
  • Coefficients from data. For building materials, use a published coefficient for 500 to 1,000 Hz from the maker’s data sheet or a reference table. For acoustic products, use the tested coefficient from an ASTM C423 report in the mounting you will use.
  • Furniture and people as sabins. Upholstered seating, curtains, rugs and people are easier to count as an allowance in sabins than as surfaces. Enter the allowance as the area and 1.00 as the coefficient, and the row adds exactly that many sabins.
  • One band at a time. Every row should use coefficients for the same frequency band. To check the bass, fill in the sheet again with 250 Hz values.

The formula

Each row adds area × coefficient in sabins. The total goes into the imperial Sabine formula:

RT60 = 0.049 × volume ÷ total sabins

Worked example

Example (fictional). The rows describe the example room, a 60-seat dining room that is not a Fibson project, with a volume of 13,200 cu ft:

Surface Material Area (sq ft) Coefficient Sabins
Floor Sealed wood 1,200 0.07 84.0
Ceiling Painted gypsum board 1,200 0.05 60.0
Storefront Glass 220 0.12 26.4
Walls Painted gypsum board 1,320 0.05 66.0
Furniture allowance Tables, chairs, bar (40 sabins) 40 1.00 40.0

The results read:

  • Surface area entered: 3,980 sq ft
  • Total absorption: 276.4 sabins
  • Reverberation time (Sabine): 2.34 s

The furniture allowance row enters its 40 sabins as 40 sq ft at 1.00, so the surface area entered is 40 sq ft more than the room’s real surfaces, which total 3,940 sq ft. The absorption and the decay time are unaffected.

Read down the sabins column. The painted ceiling and walls are 2,520 sq ft, nearly two thirds of the room’s surface, yet they contribute 126 of its 276.4 sabins. Large, hard and directly in the path of every voice, they are the surfaces worth treating.

Testing a panel plan

Add one row per panel group to see what a plan does. For panels fixed over a surface, use the net coefficient (the panel’s coefficient minus that of the surface it hides), so the covered drywall is not counted twice. The example room plan adds three rows:

Surface Material Area (sq ft) Coefficient Sabins
Ceiling clouds 16 at 4 by 4 ft, hung below the ceiling 256 0.90 230.4
Wall panels 14 at 2 by 4 ft, net of the drywall 112 0.75 84.0
Art panels 4 at 4 by 6 ft, net of the drywall 96 0.75 72.0

With those rows the total becomes 662.8 sabins and the estimate 0.98 s, about 1.0 second. The coefficients are planning assumptions, not test results for any product. To find how much absorption to add before you split it between groups, use the panel quantity calculator.

Limits

  • One band, even spread. The estimate covers one frequency band and assumes sound spreads evenly through the room. ASTM C423 notes that lab coefficients “should be used with caution” in real rooms.
  • Blank cells. A row with a missing area or coefficient adds nothing to the totals.
  • Occupancy. A furnished but empty room reads longer than the same room full of people. Say which one your allowance describes.

Next steps

Send the sheet with photos through Plan my room, along with the room measurement worksheet. In the room plan we do the same inventory band by band, with the source of every coefficient named.

Send us the room

Room size, a few photos and what happens in the space. We reply with questions or an outline of the plan.

Plan my room