NRC vs STC: what acoustic panels can and cannot do

NRC vs STC: NRC rates how much sound a panel absorbs inside a room, STC how much a wall blocks between rooms. See what panels fix and what they cannot.

A sky-blue felt sponge resting on top of a charcoal felt brick wall, soaking up a saffron puddle while a thin saffron trickle still runs down through a gap between the bricks.
Reader question
Will acoustic panels stop sound getting into or out of a room, or do they only cut the echo inside it?

Acoustic panels cut the echo and the noise build-up inside a room; they do not stop sound getting into or out of it. NRC (noise reduction coefficient) rates how much sound a surface absorbs, measured with the ASTM C423 laboratory test, while STC (sound transmission class) rates how much a wall, floor, door or window blocks, measured with ASTM E90 and rated under ASTM E413. Panels can halve a room’s reverberation time, yet each doubling of a room’s absorption lowers the level of steady noise in it by only about 3 decibels, and they do almost nothing for the neighbor’s television.

This article ties each rating to its test, shows the arithmetic behind those few decibels, maps the paths sound actually takes between rooms, and ends with a plain table of what panels fix and what they do not. Fibson Acoustics designs and makes acoustic panels to order and plans each room before anything is ordered. That means we sell absorption, not isolation, and the useful thing we can do here is help you tell the two apart before you spend money.

What NRC measures, and the test behind it

NRC is a single number, usually between 0 and about 1, that summarizes how much sound a material soaks up at four speech frequencies. It comes from a laboratory test run in a reverberation room, ASTM C423, and it says nothing about sound passing through the material to another room.

ASTM describes C423 as covering “the measurement of sound absorption in a reverberation room by measuring decay rate” (ASTM C423 scope). The lab fills a hard, echoing room with broadband noise, switches it off and times the decay, first with the room empty and then with the specimen inside. The faster decay with the specimen in place gives the specimen’s absorption.

Intertek, an accredited test laboratory, summarizes the procedure: the empty room is measured by timing how long the level takes to drop 25 decibels, with 10 decays at each of five microphone positions, and another 50 decays are measured with the specimen installed. For products that cover a flat surface, the method recommends a specimen about 8 ft wide by 9 ft long.

The definitions, in plain words

An absorption coefficient is the share of sound striking a surface that the surface absorbs. ASTM defines it ideally as “the fraction of the randomly incident sound power absorbed by the surface.” A coefficient of 0.05 means 5 percent absorbed and 95 percent reflected back into the room, which is where ordinary plaster on lath sits at 1,000 Hz in the HyperPhysics absorption table.

  • NRC is “the average of the absorption coefficients at 250, 500, 1000 and 2000 hertz, rounded to the nearest multiple .05,” per the Intertek summary.
  • SAA (sound absorption average) is the average over the twelve one-third octave bands from 200 to 2,500 Hz, rounded to the nearest 0.01. It is a finer-grained cousin of NRC from the same test.
  • Sabins are units of absorption: one sabin is one square foot of surface that absorbs everything. A 2 by 4 ft panel with a coefficient of 0.80 adds 8 × 0.80 = 6.4 sabins to a room, less whatever the wall behind it was already absorbing.

Why the same panel can show different NRCs

The way a specimen is mounted in the lab changes its numbers. ASTM E795, the companion practice that sets out test mountings, says absorption “depends not only on the physical properties of the material but also on the way in which the material is mounted” (ASTM E795 scope). A panel tested flat against the test surface and the same panel tested with an air space behind it are two different results, and a report should name its mounting type.

Coefficients can also exceed 1.00. ASTM C423 explains that “diffraction effects usually cause the apparent area of a specimen to be greater than its geometrical area,” and that for highly absorptive specimens “these values may exceed unity.” An NRC of 1.05 does not mean the panel absorbs more sound than reaches it; it means its edges add absorption beyond its face area.

The standard also asks for caution in use: lab coefficients “should be used with caution” because real installations are larger than the specimen and “the sound field is rarely diffuse.” That is why a room plan treats published coefficients as planning inputs, not promises, and why our materials and safety page explains how to read the test report behind a number. You can turn a report’s band-by-band coefficients into NRC and SAA with the NRC calculator.

An old idea with the same four frequencies

The single-number summary is older than most buildings it is used in. A 1938 National Bureau of Standards circular on architectural acoustics noted that makers of acoustic materials recommended a “noise coefficient” averaging the coefficients “at 256, 512, 1,024, and 2,048 cycles per second” to the nearest 5 percent (NBS Circular C418). Today’s NRC uses the same four octaves, rounded to standard band centers.

Because those four bands start at 250 Hz, NRC says little about bass. A panel with a strong NRC can still do little for a thumping subwoofer, and that matters again when we reach neighbor noise.

What STC measures, and the tests behind it

STC is a single number that rates how well a building element stops airborne sound passing from one room to the next. Higher is better, and it comes from a different family of tests than NRC, with two rooms instead of one and the specimen built into the opening between them.

ASTM E90 “covers the laboratory measurement of airborne sound transmission loss of building partitions such as walls of all kinds, operable partitions, floor-ceiling assemblies, doors, windows, roofs, panels, and other space-dividing elements” (ASTM E90 scope). The lab is built so the specimen is the primary path for sound between the two test rooms. ASTM’s store lists E90-23 as the active edition, as of November 2026.

ASTM E413 then turns the measured transmission loss into one number. For results from E90, “the single-number rating is called sound transmission class (STC)” (ASTM E413 scope). Cornell University’s acoustics design standard describes STC as rating “an assembly’s ability to resist airborne sound transfer at frequencies 125-4000 Hz” (Cornell 098000 Acoustics).

What STC is good for, and where it stops

ASTM E413 says these ratings “correlate in a general way with subjective impressions of sound transmission” for speech, radio, television and similar sources in offices and buildings. It also says the method is not appropriate for sources with very different spectra, naming machinery, bowling alleys and transportation noise, where a band-by-band analysis is needed. A neighbor’s bass-heavy music falls closer to that second group than to speech.

The bigger limit is the lab itself. E90 states that in buildings there are “often many other paths for sounds,” so lab ratings “do not relate directly to sound isolation in buildings” and “represent an upper limit to what would be measured in a field test.” A wall rated STC 50 in the lab is a wall that can do no better than that once built into your office.

The field and ceiling cousins of STC

Several ratings describe what happens in real buildings rather than in a lab. They all come from transmission tests, and none of them comes from the absorption test that produces NRC.

  • NIC, NNIC and ASTC come from ASTM E336, the field test between finished rooms. E336 opens by saying that isolation between two spaces depends on direct transmission through the separating partition and “any transmission along a number of indirect paths, referred to as flanking paths,” including common ducts and doors to a shared corridor (ASTM E336 scope).
  • CAC (ceiling attenuation class) comes from ASTM E1414, which simulates “a pair of horizontally adjacent small offices” separated by a partition and “sharing a common plenum space,” so the only significant path is through the ceiling and the plenum above it (ASTM E1414 scope).
  • IIC (impact insulation class) rates how well a floor-ceiling assembly reduces footfall and other impacts reaching the room below, as Cornell’s standard defines it. Panels on your ceiling do not change it.

What the numbers look like in practice

Published guidance gives a feel for the scale. GSA’s office guide calls for walls of at least STC 40 between private offices needing normal speech privacy, STC 45 for confidential speech privacy, and STC 53 to isolate video conference and training rooms (GSA Sound Matters). LEED v4.1 asks for a composite STC of 45 or NIC 40 between two private spaces and STC 50 or NIC 45 between two conference rooms, allowing 5 points less where sound masking runs at 40 dBA or more (LEED v4.1 BD+C).

GSA also describes what those classes buy. At its “confidential” level, built with a slab-to-slab partition rated NIC 45, conversation next door “is audible as muffled sound, but unintelligible.” That is the kind of change people expect when they ask whether panels will stop noise, and it comes from walls, ceilings and doors, not from what hangs on them.

NRC vs STC side by side

The two ratings answer different questions, use different tests and reward opposite kinds of material. Porous, light materials absorb well and block poorly; heavy, airtight, separated layers block well and absorb poorly.

Compared NRC and SAA STC and its field cousins
Question it answers How much sound does this surface soak up inside the room? How much sound does this wall, floor, door or window stop between rooms?
Laboratory test ASTM C423, one reverberation room, mounting per ASTM E795 ASTM E90, two rooms with the specimen between them
Rating rules NRC and SAA, defined with the C423 test ASTM E413
Frequencies covered NRC 250 to 2,000 Hz; SAA 200 to 2,500 Hz 125 to 4,000 Hz
Scale 0 to about 1; can exceed 1 because of edge diffraction Whole numbers; office walls in GSA guidance run from STC 40 to 53
Materials that score well Mineral wool, fiberglass, PET felt, acoustic ceiling tile, fabric-wrapped panels Layered gypsum, staggered or double studs, insulated cavities, solid gasketed doors
Field and related ratings Sabins per unit for baffles and objects NIC, NNIC and ASTC (field), CAC (ceilings), IIC (impacts)
Typical problem it solves Echo, muddy speech, noise build-up in one room Neighbors, private offices, conference rooms, street noise

The two scales do not convert into each other. You cannot add a panel’s NRC to a wall’s STC, and an absorption report tells you nothing about transmission. The acoustics glossary has one-line definitions of each term if you need them while reading a data sheet.

How much quieter can absorption make a room?

Each doubling of a room’s total absorption lowers the level of steady, reflected sound in it by about 3 decibels, while the reverberation time halves. That is why a treated room can sound far clearer while a sound level meter moves only a little.

The arithmetic

Sabine’s formula ties reverberation time to volume and absorption. In feet it reads RT60 = 0.049 × V ÷ A, where V is the volume in cubic feet and A is the total absorption in sabins; in meters the constant is 0.16 (HyperPhysics, Sabine formula). Double A and the reverberation time halves.

The level of sound that has bounced around the room falls more slowly. The 1938 NBS circular gives the rule engineers still use: reduction in decibels = 10 × log10(a2 ÷ a1), where a1 is the total absorption before treatment and a2 after. Doubling gives 10 × log10(2) = 3.0 dB. The same circular warned that “as a rule it is not practical to reduce the noise level more than 5 to 8 decibels, as a greater reduction requires an excessive amount of acoustic material.”

The two effects move at very different speeds, which is the whole NRC vs STC story in one table. These rows are plain arithmetic from Sabine’s formula and the NBS rule, for any room.

Total absorption after treatment Reverberation time becomes Reverberant level falls by
1.5 times before two thirds of before 1.8 dB
2 times before half of before 3.0 dB
3 times before one third of before 4.8 dB
4 times before one quarter of before 6.0 dB
10 times before one tenth of before 10.0 dB
Drop in reflected sound level against the increase in total absorption A curve rising quickly then flattening: doubling a room's absorption lowers the reverberant level by 3.0 decibels, the fictional example dining room's 2.4 times increase gives 3.8 decibels, four times gives 6.0 and ten times gives 10.0. A shaded band marks the 5 to 8 decibel range the 1938 NBS circular called the practical limit. Practical limit in NBS C418: about 5 to 8 dB 0 dB36912 1×2×3×4×5×6×7×8×9×10× Total absorption after treatment, as a multiple of before 2× = 3.0 dB Example room, 2.4× = 3.8 dB 4× = 6.0 dB 10× = 10.0 dB Drop in reverberant level, dB
Curve computed from the NBS rule, reduction = 10 × log10(absorption after ÷ absorption before), in National Bureau of Standards Circular C418 (1938), which also gives the 5 to 8 dB practical limit. The 2.4× point is the fictional example dining room described below, not a measured result.

Example (fictional). The site’s example room is a 60-seat dining room, 40 by 30 ft with an 11 ft ceiling, so its volume is 13,200 cu ft. It is not a Fibson project, and its coefficients are planning assumptions. Unoccupied and furnished, it has 276.4 sabins, so RT60 = 0.049 × 13,200 ÷ 276.4 = 646.8 ÷ 276.4 = 2.34 s. A plan of 16 ceiling clouds, 14 fabric wall panels and 4 printed art panels adds 386.4 sabins, for 662.8 in total, and RT60 = 646.8 ÷ 662.8 = 0.98 s.

The reverberation time falls by more than half. The level of steady reflected sound falls by 10 × log10(662.8 ÷ 276.4) = 10 × log10(2.40) = 3.8 dB. Both numbers describe the same panels, and both are right.

Why the room still sounds much better

A 3.8 dB drop sounds small, but it is not the main thing a diner notices. Halving the decay means each syllable stops smearing into the next, so speech is clearer at the same level, and the room settles faster after a burst of laughter or a dropped tray.

Crowds add a second effect. People raise their voices as background noise rises, the Lombard effect, and lower them as it falls. In Rindel’s restaurant model, the ambient level from talking guests is 93 minus 20 × log10 of the absorption per speaking person, so the same change in absorption is worth twice as many decibels as in the 10 × log10 rule (Rindel 2019). In that model a doubling of absorption, with the same number of people talking, lowers the crowd’s noise by about 6 dB.

Two cautions keep that honest. People absorb sound too, from 0.2 to 0.5 square meters each in Rindel’s paper, so the occupied room starts with more absorption and the ratio panels achieve is smaller than in the empty-room estimate. And the rule describes the reflected sound that fills a room, not the direct sound from the person speaking to you, which panels do not change.

Why 3 dB is not soundproofing

The difference between absorption and isolation is a difference in scale, not just in kind. A few decibels off the reverberant level is real, but it does not turn “garbled words” next door into “muffled sound, but unintelligible,” the step GSA describes between its normal and confidential privacy levels. That step comes from the partition, the ceiling path and the door, which is why panels are not a soundproofing product and should not be sold as one.

Why panels on a wall do not raise its STC

STC belongs to the whole wall assembly as tested, and a porous panel hung on the face of that wall adds almost no mass and does nothing to seal it. Transmission loss improves with mass, air space, absorptive fill inside the cavity and separation between the two faces.

Cornell’s standard lists the ways to improve the transmission loss of an assembly: “adding mass to the assembly,” “increasing or adding air space,” “adding absorptive material in the partition,” “staggering studs or using dual studs,” specifying lighter-gauge studs and increasing stud spacing. Look closely at the third item. Insulation inside the stud cavity is part of the tested wall; the same material on the room side of the drywall is acting on the room, not on the wall.

An absorptive panel is built to let sound in. Fabric, felt and fibrous cores are porous so that sound can enter and lose energy as heat. That is the property ASTM C423 measures, and it is the opposite of what an airtight, massive barrier needs.

What panels do for sound arriving from next door

Panels in the quiet room are not useless against intruding noise; they work on it the way they work on any sound in that room. ASTM E336 notes that isolation between spaces is “also influenced by… absorption in the receiving space.” Sound that gets through the wall then reflects around your room, and absorption lowers that build-up by the same 10 × log10 rule.

Example (fictional). A 12 by 11 ft home office with an 8 ft ceiling (1,056 cu ft) shares a wall with a neighbor’s living room. Using planning assumptions of 0.07 for the wood floor, 0.05 for painted gypsum and the door, 0.12 for a 20 sq ft window and 10 sabins for the desk, chair and shelves, the room has about 45.6 sabins. RT60 = 0.049 × 1,056 ÷ 45.6 = 51.7 ÷ 45.6 = 1.13 s.

Six 2 by 4 ft panels at an assumed 0.80, covering gypsum at 0.05, add 6 × 8 × 0.75 = 36 sabins, for 81.6 in total. RT60 falls to 51.7 ÷ 81.6 = 0.63 s, and video calls sound much less hollow. The neighbor’s television, reverberating in the office, drops by 10 × log10(81.6 ÷ 45.6) = 2.5 dB. The wall’s STC has not changed, and the television is still there.

That example is the honest middle ground. If the complaint is that your own voice rings on calls, panels are the right tool; the residential version of that question is covered in our article on echo in open-plan homes. If the complaint is the neighbor, a 2.5 dB softening of the room’s build-up is a side benefit, not a fix.

Where sound leaks between rooms

Between two rooms, sound takes every path it can find: through the wall, over it through a shared ceiling plenum, under and around the door, through ducts and through back-to-back outlets. The weakest path sets what you hear, which is why isolation measured in finished buildings often falls short of a wall’s lab rating.

Paths sound takes inside a room and between two rooms, with the test that rates each A section through two rooms that share a ceiling plenum. In the left room, sound reflects between surfaces and a wall panel absorbs some of it, rated by ASTM C423 as NRC and SAA. Arrows show sound reaching the right room through the wall, rated by ASTM E90 as STC; over the wall through the shared plenum, rated by ASTM E1414 as CAC; and under the door. A note says ASTM E336 measures all paths together as NIC, NNIC or ASTC. Room with the talker Panel absorbs inside the room: ASTM C423 (NRC, SAA) Next room Over the wall through the shared plenum: ASTM E1414 (CAC) Through the wall: ASTM E90 (STC) Under and around the door Between finished rooms, ASTM E336 measures every path at once: NIC, NNIC or ASTC
Diagram for illustration, not to scale. Test names from the ASTM scope pages for C423, E90, E413, E336 and E1414, checked November 2026; the door gap is drawn in the wall for clarity.

The ceiling plenum

Many offices build walls up to a suspended ceiling and stop there, leaving one shared space above every room. GSA’s guide is blunt: where the partition stops at the ceiling, “which is typical commercial office construction,” the blocking action “is not nearly as effective because sound leaks are inevitable at the ceiling plane.” Cornell’s first recommendation is to “extend walls and gypsum board to the structural deck” and fill the flutes between the top track and a metal deck.

Where walls do stop at the ceiling, the ceiling itself becomes part of the barrier, and that is what CAC rates. Cornell pairs the two jobs in one line, asking designers to “specify acoustical ceiling tiles for a 0.75 NRC (minimum of 35 CAC).” The same tile has to absorb inside the room and block over the wall, and each job has its own test.

Doors, glass and the gaps around them

Doors are usually the weakest part of a wall. GSA rates hollow-core doors “only good to poor,” asks for a continuous closed-cell foam seal on three sides and a sweep or drop seal at the undercut, and notes that glass sliding and pivot doors generally have low STC ratings. Cornell recommends heavy solid-core or insulated metal doors, gasketed around the perimeter, and says to avoid louvered or undercut doors.

Cornell lists the other weak points as “doors, sidelites, storefront systems, clerestories, exterior windows, electrical outlets and air transfer,” and it adds a warning worth repeating: “the specification/construction of a high STC wall may not address the NIC requirement.” Back-to-back electrical boxes should be separated by a stud and sealed with putty pads, and every corner, ceiling and floor joint sealed with acoustical caulk.

How far field results fall

GSA says it “is not unusual for NIC to vary by ten points or more below the STC,” and puts the gap down to installation and detailing. Cornell, describing well-built assemblies, says the field rating ASTC “is typically within 0 - 5 decibels of the laboratory STC rating for a well-constructed assembly.” Read together, the lesson is that a good wall rating is necessary but not enough; the details around it decide the result.

A quick leak hunt you can do yourself

You do not need instruments to find the worst path. Play steady music or a radio at a moderate level in one room and close the door.

  1. Stand in the other room and listen with one ear close to the door edges, the threshold and any glass beside the door.
  2. Listen at outlets and switches on the shared wall, and at supply and return grilles.
  3. If there is a suspended ceiling, lift one tile near the shared wall and listen above it.
  4. Note where the sound is clearly louder. That spot, not the middle of the wall, is where money will do the most good.

What panels fix and what they do not

Panels fix problems that happen inside one room: echo, unclear speech and noise building up as a room fills. They do not fix sound moving between rooms, because that is governed by walls, ceilings, floors, doors and the gaps around them.

Problem Do panels help? Why What to look at instead or as well
Echo and ringing in a hard room Yes, directly Absorption shortens reverberation time (Sabine) Ceiling and wall coverage, mounting type
Muddy speech in a meeting room Yes Fewer late reflections at the listener Panel placement near talkers, camera and microphone position
A dining room that gets louder as it fills Yes, partly A few dB off the reflected level, more in a crowd per Rindel’s model Seat count, table spacing, music level
Flutter echo between parallel walls Yes, if one wall of the pair is treated Breaks the repeated reflection path Where the panels go, not just how many
Neighbor’s television or music through a shared wall No Wall STC is unchanged; panels only soften the build-up in your room Sealing gaps, the wall assembly, a contractor’s assessment
Footsteps from the unit above No Impact noise is rated by IIC for the floor-ceiling assembly The floor above: underlayment, rugs, the assembly
Private office conversations overheard No Leaks through the wall, plenum, door and ducts Walls to the deck, CAC ceilings, gasketed doors, masking
Conference room heard in the corridor No Door and glass sidelites are usually the weak path Solid gasketed doors, sealed glazing
Street noise through windows No Window and facade transmission Window ratings; LEED asks for at least STC 35 for school exterior windows
Open-office distraction Partly Absorption is one of three tools GSA’s Absorb, Block, Cover: absorption plus barriers plus masking

The last row deserves its own article, because absorption alone rarely gives open-office privacy. GSA frames office noise control as “Absorb, Block, Cover,” and the trade-off between more panels and a masking system is set out in our article on sound masking vs acoustic panels.

Matching the fix to the problem

Most complaints fall into one of three patterns, and each points to a different first move. Decide which pattern you have before you buy anything.

Noisy neighbors in an apartment or shared house

The sound starts on the other side of a wall or floor, so the fix is in the wall or floor. Absorption in your room will soften what does get through by a couple of decibels, as the home office example showed, but it will not change what you can hear of a conversation or a bass line.

  1. Do the leak hunt above. Outlets, door edges and gaps at the floor are common culprits, and sealing them is the cheapest step.
  2. Fit a solid door with perimeter seals and a sweep or drop seal if the problem enters from a hallway.
  3. For footsteps from above, the remedy sits in the floor assembly above you, which usually means a conversation with the owner or the building.
  4. For the shared wall itself, ask a contractor or acoustical consultant about added mass, a separated layer or cavity insulation; those are the levers Cornell lists.
  5. Add panels only if your own room also echoes. They will make it pleasant to be in; they will not make it private.

A private office or conference room that leaks

Overheard conversations in an office are almost always a path problem. GSA’s myth box puts it plainly: rooms with closed doors keep conversations private “only if adequate measures have been taken in construction to prevent sound from leaking around doors, through walls, through the ceiling plenum, through ducting.”

  1. Check whether the wall stops at the suspended ceiling. If it does, the plenum is a likely path; ask about extending the wall or a plenum barrier, and check the ceiling tile’s CAC.
  2. Check the door: hollow core, undercut, missing seals and glass sidelites are frequent weak points.
  3. Check ducts and return-air paths that connect rooms through the plenum.
  4. Consider masking where an open area borders private rooms; LEED allows lower isolation where masking of at least 40 dBA is designed in.
  5. Add panels inside the room for clarity on calls and in meetings. They improve how the room sounds to the people in it.

A loud dining room

Here panels are the main tool, because the problem is inside one room. The noise comes from guests, kitchen sounds and music reflecting off hard floors, ceilings, glass and walls, and absorption shortens that reflection and lowers the build-up. Our room acoustic assessment starts with exactly this kind of surface-by-surface estimate.

Absorption has limits even here. Rindel’s work ties restaurant noise to the number of guests and the room’s volume as well as its reverberation time, so seat count, table spacing and music level belong in the same conversation as panels.

Reading a product page or data sheet without being misled

Check which test a number comes from before you compare it. An absorption number belongs to ASTM C423 and a stated mounting; a transmission number belongs to ASTM E90 and the whole assembly that was built into the test opening.

  1. NRC or SAA without a report. Ask for the lab report: the lab, the C423 edition, the date and the E795 mounting type. A number with no report behind it cannot be compared with anything.
  2. An STC printed for an absorptive panel. Ask for the E90 report and what assembly was tested. If the number describes a wall with the panel on it, the wall did the work.
  3. “Soundproofing panels.” Absorptive panels do not soundproof anything, and no absorption test measures transmission. Treat the wording as a sign to read the rest of the page carefully.
  4. Coefficients above 1.00. These come from edge diffraction in the test, which ASTM C423 explains, and they do not mean more than all of the sound is absorbed.
  5. A single number for a bass problem. NRC averages 250 to 2,000 Hz. If the problem is low-frequency, ask for the full band-by-band table.
  6. One report quoted for many products. A report covers the material, thickness, facing and mounting tested. A different core, a printed fabric or a deeper air gap is a different specimen.

For the specification side of the same questions, including how to write them into a contract, see our guide to specifying acoustic panels. Fire performance is a separate test again, with its own documents, and our materials and safety page explains what to ask for.

Questions people ask about panels and noise

A few questions come up whenever absorption and isolation get mixed together. The short answers below follow from the tests already described.

Will panels on both sides of a shared wall help?

Each room gets its own small benefit and nothing more. Panels in your room lower the build-up of whatever sound reaches it, by 10 × log10 of your room’s absorption ratio; panels in the neighbor’s room do the same for their side. The sound crossing the wall is set by the wall, its edges and the door, and none of that has changed.

Is acoustic foam any different from a fabric panel?

In test terms, no. Any product sold on its NRC is an absorber by definition, because NRC only exists as a result of the absorption test. Foam, felt, fabric-wrapped mineral wool and acoustic ceiling tile differ in how much they absorb, at which frequencies and how they look and wear, but none of them is rated for blocking by that number.

Can thick panels or bass traps keep out low-frequency noise from next door?

They can absorb more low-frequency sound inside your room than thin panels do, which helps a room that booms. They do not stop bass arriving through the structure. ASTM E413 itself says single-number transmission ratings are not appropriate for sources with spectra very different from speech, and the levers that block low frequencies are the ones Cornell lists: mass, air space and separating the two faces of the wall.

Do rugs and curtains count?

Yes, as absorption. GSA’s guide lists carpeting, curtains, furniture finishes, acoustic ceiling tiles and hanging clouds among the ways to absorb sound in an office. They follow the same rules as panels: they shorten reverberation and lower the build-up in the room, and they do not raise the wall’s rating.

What to do next

Start by naming the problem in one sentence: “our room echoes,” “people can hear us next door,” or both. The first is absorption; the second is isolation; both means two separate pieces of work, usually by two different trades.

  • If the room echoes: estimate its reverberation time with the reverberation time calculator, or send the room’s size, photos and use for a written estimate through our room acoustic assessment.
  • If sound travels between rooms: do the leak hunt, check doors, ceilings and outlets, and talk to a contractor or acoustical consultant about the wall, floor or ceiling assembly. A panel plan that ignores this would set the wrong expectation, and ours will say so.
  • If you are comparing products: collect the C423 reports with their mounting types for absorbers, and E90 reports for anything sold as a barrier, and compare like with like.
  • If you are unsure which problem you have: describe what you hear, where you hear it and when, and send it to us. We will tell you whether panels are part of the answer before anything is quoted.