Sound masking vs acoustic panels is not an either-or choice, because they change different things. Panels absorb sound, so a room rings less and voices fade faster with distance; masking adds a steady, engineered background sound, so speech that does reach you is harder to understand. An open office needs more absorption when people complain that it is loud and echoey, needs masking when the ceiling is already absorptive but nearby conversations are still easy to follow in a quiet room, and usually needs both when privacy matters. When a conversation must stay confidential, only an enclosed room will do.
A note on where this comes from: Fibson designs and makes acoustic panels to order and does not sell or install sound masking systems. That gives us no reason to favor masking and an obvious reason to favor panels, so every rule below is tied to a published source you can check. This guide is for office managers, workplace strategists and designers deciding what to spend on next.
What sound masking and acoustic panels each do
Panels and masking act on opposite sides of the same ratio. Whether you can understand a colleague’s words depends on how loud their voice is at your desk compared with the background sound around you. Panels lower the voice part of that ratio by removing reflected sound. Masking raises the background part.
A continuing-education course on speech privacy, written by a masking manufacturer, puts the arithmetic simply: if a wall reduces a voice by one decibel, “the signal-to-noise ratio drops by a decibel. An identical drop occurs when the masking volume is raised by one decibel” (BNP Media CE course). The US General Services Administration names the three tools together: “the ABC’s of noise control: Absorb, Block, Cover” (GSA Sound Matters).
| Compared | Acoustic panels (absorb) | Sound masking (cover) |
|---|---|---|
| What it is | Porous panels, clouds, baffles and absorptive ceiling tile | Loudspeakers, usually above or in the ceiling, playing a shaped, steady sound |
| What it changes | Reflected sound: reverberation time, build-up, how fast speech fades with distance | Background level: how much speech stands out above it |
| Best at | Echo, ring, the roar of a busy floor, raised voices | Conversations that are clear because the room is quiet |
| What it cannot do | Reduce a voice arriving directly at the next desk | Reduce echo or the loudness of a room; it adds sound |
| How it is specified | Coefficients and NRC from ASTM C423 tests; reverberation time targets | A level in dBA, a spectrum and a uniformity tolerance |
| How it is checked | Reverberation time and ISO 3382-3 spatial decay | Level and spectrum measured at ear height after tuning |
The Construction Specifier put the limit of masking bluntly in a 2016 article: “sound masking does not stop sound from travelling. Instead, it works by playing audible noise into a space to make the background sound level slightly louder than the sounds of people talking” at a distance (The Construction Specifier). Panels have the mirror-image limit: they remove reflections, not the direct path from one mouth to the next ear, as the sibling guide on where acoustic panels go in an open office explains.
Why a quiet office can feel less private
An office can be too quiet for privacy. When the background is very low, even distant, quiet speech stands out clearly against it, and every word is easy to follow.
GSA’s guide says it directly: “Most contemporary open workspaces are simply too quiet to be acoustically comfortable. Though this seems counter-intuitive, a low level of background noise allows interruptions to contrast with the quiet, causing a greater distraction than if the space had a higher level of background noise.” The BNP course points to one cause: improvements in construction materials, mechanical systems and office equipment have lowered background levels, and the resulting “pin-drop” environment “allows conversations and noise to easily be heard and understood, even from a distance”.
Why speech is the problem, not noise in general
ISO’s announcement of its open-plan measurement standard explains why voices matter more than other sounds: “Conversations are particularly disturbing because of the information content. Speech recognition notoriously distracts much more than other noises of a similar level.” It adds the other side of the effect: “if numerous people are speaking at the same time at a sufficient distance, we are no longer able to recognize what they are saying, and the noise generated has a beneficial masking effect on speech nearer to us” (ISO news, archived).
That is why a busy, humming floor can feel more private than a half-empty one. It is also why absorption on its own can sometimes make privacy slightly worse. Yadav and colleagues, in the 2025 study discussed below, note that strong reverberant fields can blur successive sounds together and lower intelligibility, acting a little like masking (Yadav et al., 2025). Remove that reverberant blur with panels in an office that is otherwise quiet, and a nearby voice can become a little clearer. That is not an argument against absorption, which reduces noise disturbance across the floor; it is the reason absorption and masking are usually designed together.
Privacy has levels
GSA’s guide defines levels of speech privacy from the ASTM standards. Under normal privacy “you cannot understand the whole conversation”, and it is “the baseline for achieving acoustical comfort in most ‘open’ offices”. Under confidential privacy only about 2% of what is said can be understood. GSA relates these to a privacy index: “understanding 2 out of 10 words will render normal speech privacy, understanding 5 out of 100 words will render confidential speech privacy.” An acoustical consultant quoted in the guide adds that “most commercial office buildings provide a PI less than 80”, the threshold GSA gives for normal privacy.
How speech privacy is measured: ISO 3382-3 in plain terms
ISO 3382-3 measures how one voice fades across an empty open office, and from that it derives distances that describe privacy. The 2022 edition “specifies a method for the measurement of room acoustic parameters in unoccupied open-plan offices” for the condition “when one person is speaking”, focusing “on spatial decay of speech” rather than the decay of sound over time (ISO catalog page, archived).
The measurement is made along a line of workstations, with a loudspeaker playing a test signal shaped like typical speech. Yadav and colleagues summarize the single-number results:
| Measure | Plain meaning | What improves it |
|---|---|---|
| D2,S, spatial decay rate of speech (dB) | How much a voice drops each time you double your distance from the talker | Absorption, especially overhead; screens |
| Lp,A,S,4m, speech level at 4 m (dB) | How loud a normal voice still is about 13 feet away | Absorption; screens |
| rC, comfort distance (m) | Distance at which the speech level falls below 45 dB | Absorption; screens |
| rD, distraction distance (m) | Distance at which the speech transmission index falls below 0.5, so speech is no longer easily understood | Absorption, screens and a higher, steadier background (masking) |
| Lp,A,B, background level (dB) | The A-weighted background sound at the workstations | Masking raises it; quieter ventilation lowers it |
ISO’s 2013 announcement explains the idea behind the distances in words. Privacy distance is “the distance from a source at which speech is no longer intelligible due to attenuation and background noise”, and “in some offices, however, this is longer than the total length of the office, which means privacy is not possible”. Distraction distance is “the distance where speech is only partly intelligible, but mostly contributes to the background noise.”
The US method: articulation index and privacy index
US practice also rates privacy between two specific positions rather than along a line of desks. The BNP course describes the ASTM E1130 method, “Standard Test Method for Objective Measurement of Speech Privacy in Open Plan Spaces Using Articulation Index”: measure how much a voice drops between the talker’s position and the listener’s, subtract that from a standardized normal voice level, compare the result with the background in each third-octave band from 200 to 5,000 Hz, and weight and sum the differences into an articulation index. GSA’s privacy index expresses the result the other way round, as the share of words a listener cannot understand: if a colleague “can understand 5 words out of 100, the office has achieved a PI of 95”. Both methods put the voice and the background in the same calculation, which is why both respond to masking as well as to absorption and blocking.
What this means for the choice
The table shows the division of labor. Comfort distance and the speech level at 4 m are mostly about absorption and screens; they do not include the background at all. Distraction distance depends on speech intelligibility, so it responds to both absorption and background. That is the measurable version of “do both”: absorption makes the voice fall faster, masking lifts the floor it falls toward, and the distance at which speech stops being easy to follow shrinks from both directions.
Example (fictional). The figure above uses invented numbers. Office A has a hard ceiling: speech is 52 dB at 4 m and falls 5 dB per doubling of distance. Office B has an absorptive ceiling: 48 dB at 4 m, falling 7 dB per doubling. In a quiet room with a 35 dB background, Office B’s voice reaches the background at 4 × 2^((48 − 35) ÷ 7) = 4 × 2^1.86 ≈ 14.5 m; Office A’s would need 4 × 2^3.4 ≈ 42 m, longer than most floors. With masking at 45 dB, Office A’s crossing moves in to 4 × 2^1.4 ≈ 10.6 m, and Office B’s to 4 × 2^0.43 ≈ 5.4 m. Neither change alone gets as close as both together.
Two floors, two answers
Example (fictional). Two invented office floors, not Fibson projects, show how the measurements point to different purchases.
Floor A. Eighty desks under a suspended ceiling whose tile maker documents NRC 0.90, carpet tile, low screens. The estimated reverberation time is 0.6 seconds, under the LEED reference. A sound level meter at seated ear height reads 37 dBA with the ventilation running. People say they can follow every word of their neighbors’ calls and avoid personal calls at their desks. The ceiling already meets GSA’s figure, so more panels would add little. The background is low, the complaint is about words, and the answer is masking designed by a consultant, plus two small rooms for long calls.
Floor B. Forty desks under an exposed deck, a polished concrete floor and a long glass wall. The estimated reverberation time is 1.6 seconds, twice the LEED reference. The meter reads 44 dBA from exposed ductwork. People say the floor is loud by mid-morning and they raise their voices on calls. The complaint is about noise, the background is already in the mid 40s, and the answer is absorption under the deck and on the walls, then a fresh measurement. Masking may never be needed here.
What the 2025 field study found
The largest recent field test of these measures is a 2025 study in The Journal of the Acoustical Society of America by Yadav, Kim, Hongisto, Cabrera and de Dear. It measured 28 open-plan offices in nine buildings in metropolitan Australia to ISO 3382-3, recorded sound during working hours, and surveyed 349 occupants (Yadav et al., 2025). Its findings are directly relevant to the masking question, with caveats the authors state themselves.
Lack of privacy weighed more than noise
The study modeled overall acoustic dissatisfaction as two factors, noise disturbance and lack of privacy. The contribution of lack of privacy “was 25% higher than noise disturbance in predicting acoustic dissatisfaction”. For a facilities team, that suggests the complaint “I can hear everything” and the worry “everyone can hear me” deserve as much attention as “it’s loud”.
Level-based measures beat distraction distance
The speech level at 4 m and the comfort distance “were better in predicting these factors than distraction distance”. That runs against an earlier study in which distraction distance was the most consistent predictor, and the authors say plainly that their result “contradicts previous findings, which may partly be due to the cross-sectional study design”. They suggest one reason: the earlier study’s offices were quiet, with a mean background of 35.5 dB, and relatively well absorbed, so they likely “had inadequate speech/sound masking from nearby talkers”. In other words, where nothing covers speech, intelligibility-based measures matter most. They also found that some trends ran “against expectations based on ISO 3382-3” and concluded that the standard’s criteria for good and bad conditions “need a critical overhaul”.
Background sound mattered, within limits
None of the 28 offices had an electronic masking system, but their background levels, measured with the ventilation running, varied widely, from 35.6 to 51.0 dB, with an average of 42.5 dB. Offices with higher background levels had less dissatisfaction with lack of privacy, “which is expected to an extent although exorbitant Lp,A,B values can be problematic”. The authors warn that people are likely to start raising their voices (the Lombard effect) when the background exceeds about 43.3 dB, and conclude that “inordinately high HVAC noise level is not recommended here over sensible room acoustic planning, which would instead involve designing for sufficient level of sound masking along with sound absorption.”
What occupants did about it
Asked how they cope with noise at their workstation, 55% chose listening to music on headphones, 40% taking a break and 33.5% moving elsewhere. The majority (52%) said they were most bothered by intelligible conversations among several people. Both findings point at speech, not general noise, as the problem to design for.
How far to trust it
The study is cross-sectional, its sample included few offices that met ISO 3382-3’s criteria for good conditions, and it included no offices with masking systems, so it cannot measure what a tuned masking system adds. Treat it as good evidence that privacy matters and that background sound and absorption both play a part, not as a calibration for your floor. The sibling article on what research says about open-office noise and work sets this study alongside the evidence on concentration and wellbeing.
What masking levels standards and consultants cite
Published guidance puts open-office masking in a narrow band around the mid to high 40s in dBA, with lower levels in enclosed offices and meeting rooms, and asks for the level to be even across the floor.
| Source | Open office | Enclosed office | Meeting or conference room | Other requirements |
|---|---|---|---|---|
| GSA Sound Matters | 45 to 48 dBA, “tuned to group zones” | 40 to 42 dBA (normal privacy) | Not stated | Open plan background NC 40 maximum |
| LEED v4.1 BD+C | Must not exceed 48 dBA | Must not exceed 45 dBA | Must not exceed 42 dBA | Masking plus HVAC within the cap; ±1 dBA overall uniformity; ±2 dB per third-octave band from 100 to 5,000 Hz (ASTM E1573-18); set by an acoustical professional |
| Cornell 098000 | 45 to 50 dBA, citing WELL design guidelines | Not stated | Not stated | Masking locations identified in schematic design |
| BNP Media course (masking maker) | Up to 48 dBA | 40 to 45 dBA | Not stated | Tune after ceilings and furniture are in, before occupancy |
| The Construction Specifier (2016) | 42, 45 or 48 dB, “the typical industry target” | Not stated | Not stated | Aim for ±1 dB across the space |
| NAIOP, quoted second-hand in the Propmodo article | 46 to 50 dB “most effective ambient noise level” | Not stated | Not stated | Secondary source; NAIOP’s original not seen |
Three points come out of the table. First, the open-office figures are broadly consistent across very different sources, from 42 to 50 dB. Second, LEED caps meeting rooms lower than open offices, which matters because a masking system that covers the whole floor will also reach the rooms used for video calls. Third, uniformity is part of the specification, not a refinement. The Construction Specifier article explains why: where masking is uneven, with louder and softer spots, “a listener could move to a quieter spot and hear conversations that should otherwise have been covered”.
What masking sounds like
A masking system is not a fountain or a playlist. LEED requires a spectrum that conforms to the National Research Council of Canada’s optimum masking spectrum, or one an acoustical engineer specifies. The BNP course describes a curve “defined in third-octave bands” from about 100 to 5,000 Hz, and notes that most people compare a well-tuned system to “softly blowing air”. The Construction Specifier article warns that water features, rain sounds and background music “are not effective or reliable for conference room privacy”, because their level is uneven and sounds that draw attention to themselves add distraction.
Masking adds to what is already there
Sound levels add by energy, not arithmetic, and LEED’s caps apply to masking and ventilation noise combined. The decibel addition calculator does the sum; the example below shows why it matters.
Example (fictional). Suppose ventilation in an open area measures 40 dBA and a masking system is set to 45 dBA. Combined: 10 × log10(10^4.0 + 10^4.5) = 10 × log10(10,000 + 31,623) = 10 × log10(41,623) ≈ 46.2 dBA, inside LEED’s 48 dBA open-office cap. In a conference room where ventilation measures 38 dBA, masking set at 40 dBA gives 10 × log10(6,310 + 10,000) = 10 × log10(16,310) ≈ 42.1 dBA, just over LEED’s 42 dBA cap for conference rooms. The masking level has to come down, or the ventilation has to get quieter.
Common misunderstandings about masking and panels
Five beliefs come up in almost every conversation about office noise. Each has a grain of truth and a misleading conclusion.
- “Masking is just white noise.” The Construction Specifier article calls it “a band-limited pink noise with some tonal balancing” and notes that it is colloquially called white noise. The BNP course calls both terms incorrect and describes a specific curve defined in third-octave bands. Either way, a tuned masking spectrum is shaped to cover speech comfortably, and LEED names a reference spectrum rather than a type of noise.
- “Panels make an open office private.” Panels reduce reflected sound. The direct voice from the next desk is unchanged, and in a quiet room it can sound slightly clearer once the reverberant blur is gone.
- “Masking makes people talk louder.” The 2025 study cautions that people are likely to raise their voices once the background exceeds about 43 dB. Published masking levels for open offices sit a little above that, at 45 to 48 dBA, so the level is a design decision to make with a consultant and to check after tuning, not a dial to turn up.
- “Masking adds 10 STC points to a wall.” The BNP course reports this phrase and explains its origin: masking typically raises the background in closed rooms by about 5 to 12 dBA. The wall is unchanged. What changes is the ratio between the voice that gets through and the background on the listener’s side.
- “Masking only belongs in open areas.” The BNP course, written by a masking maker, argues for covering closed rooms too, because leaving them out can make their background lower than the open plan around them, by as much as 10 to 12 dBA in its estimate. LEED’s lower caps for enclosed offices and conference rooms show that closed rooms can have masking, at their own levels.
When more absorption is the answer
Choose more absorption first when the complaints are about loudness, echo and build-up rather than about overheard words, or when the ceiling is still hard. Masking on top of a reverberant room adds sound to a room that already has too much.
Absorption comes first when:
- Reverberation time is above the reference. LEED v4.1 lists under 0.8 seconds for an open-plan office without masking. A hard ceiling or exposed deck that leaves the floor well above that needs absorption before anything else.
- The ceiling is below the guidance. GSA asks for NRC 0.9 on the whole ceiling of an open plan workspace. Acentech’s Ioana Pieleanu told Propmodo any ceiling treatment should be at least NRC 0.7.
- People describe noise, not words. “It’s loud”, “it gets louder through the day”, “I have to raise my voice” all point at reverberant build-up.
- The zone is meant to be lively. GSA contrasts “the library”, where privacy and quiet are expected, with “the bazaar”, where “sharing is the norm” and “noise is far more acceptable”. Collaboration zones are bazaars. They need absorption to stop the din, not masking to hide what is said.
- The background is already moderate. If ventilation already provides a steady background in the mid 40s dBA across the area, adding masking raises the level for little privacy gain; measure before you buy.
The 2025 study supports this order. In its offices, more absorption, seen as lower speech levels at 4 m and shorter comfort distances, “reduced dissatisfaction with noise disturbance in general, which is as expected”. The open office acoustics checklist helps you separate noise complaints from privacy complaints before deciding.
When masking is the missing piece
Add masking when the ceiling and screens are already doing their job and people still follow conversations two or three desks away, especially in a quiet building. In that case the voice is no longer the problem; the silence around it is.
Masking is likely to help when:
- Absorption is in place. The ceiling meets the guidance above, reverberation is near the reference and screens are where they should be, but complaints about overheard conversations continue.
- The background is low. GSA’s guidance is to “minimize HVAC background (BG) and provide masking to make BG uniform”. A sound level meter reading at ear height, at a quiet time with ventilation running, tells you where you start.
- Private offices have walls only to the ceiling. GSA’s requirements accept NIC 35 between private offices with masking against NIC 40 without, and LEED lets the required ratings drop by 5 points where masking of at least 40 dBA is designed by an acoustical professional.
- Glass rooms leak. For glass-fronted meeting rooms, The Construction Specifier article calls masking “a contingency plan acknowledging some sound energy will escape the room”, covering speech that escapes through glass, door gaps and the ceiling.
- Work changes through the day. Cornell’s standard suggests considering masking for spaces “that fluidly change from presentation mode to group collaboration mode”.
Masking needs absorption to work well
Consultants pair the two. The Propmodo article, reporting Pieleanu’s advice, describes “a sound absorptive ceiling treatment” used “alongside a well-designed electronic sound masking system to achieve optimal speech privacy”. The 2025 study ends on the same pairing: “sufficient level of sound masking along with sound absorption”. Rockfon’s acoustician Gary Madaras, writing for a ceiling maker, lists spacing people out, overhead absorption, zone barriers and masking together as the way to reach “acceptably small distraction distances” (Rockfon).
How a masking system is laid out
Masking loudspeakers are usually installed in a grid in or above the ceiling. The BNP course describes open-plan loudspeakers “typically located according to a standard grid at 15-foot spacing”, recommends that each closed room have its own loudspeaker on its own control zone, and describes third-octave equalization so that each zone can be tuned to the specified curve. That layout is one more reason to coordinate masking with the ceiling plan: loudspeakers, clouds, baffles, lights and sprinklers all compete for the same space. The BNP course also notes that the masking sound changes as it interacts with the layout and furnishings, which is why the system is tuned after they are in place.
Practical cautions before you commission masking
- It must be tuned on site. The BNP course says tuning should happen after ceilings and furniture are installed, with mechanical systems at daytime levels, before occupancy or after hours, measuring at ear height.
- Meeting rooms need their own settings. LEED’s 42 dBA cap for conference rooms is lower than its open-office cap. Video-call rooms need a level that does not compete with the call.
- Personal control has limits. The BNP course recommends that occupants of private offices and meeting rooms can adjust the volume, but not mute it or lower it beyond a set limit, because “speech privacy will suffer”.
- Accessibility deserves a conversation. GSA’s 2011 guide notes that “the US Access Board does not have any information on masking sound and how it affect access for the disabled both the hard of hearing and blind”. Involve staff who use hearing aids or rely on sound for orientation when you trial a system.
- Ask who designs it. LEED requires an acoustical professional to set the level. Fibson can tell you where absorption should go first; a masking system should be designed and tuned by a consultant or a masking supplier.
When only an enclosed room will do
Some conversations need confidential privacy, and an open floor cannot provide it, whatever the mix of panels and masking. Plan enclosed rooms for those conversations, and treat them as a separate problem from the open floor.
GSA is unambiguous: confidential privacy, where “the meaning of conversation cannot be determined by a casual listener”, is “extremely difficult to achieve” in an open-landscape office, “therefore, it is essential to design enclosed rooms”. Rockfon’s Madaras makes the same point: “In many cases, achieving speech privacy in open spaces may be impractical. If we want privacy, we may need to move our conversation to private, enclosed spaces.”
Typical cases
- Human resources, legal, medical and financial conversations.
- Managers’ one-to-one meetings.
- Frequent or long video calls, which disturb the floor and are overheard by it.
- Interviews and client calls that need to sound professional at the far end.
What makes an enclosed room private
Walls, doors, ceilings and glass block sound; panels inside the room only shorten its echo. GSA’s guide asks for STC 45 walls to separate conference rooms and executive offices that need confidential privacy, and STC 53 to isolate video conference and training rooms. The Construction Specifier article works through GSA’s speech privacy potential, the sum of a partition’s rating and the background level: an STC 35 demountable wall with 30 dB of background scores 65, rated “poor”, while either an STC 45 wall or masking that raises the background to 40 dB brings it to 75, rated “good”. The BNP course adds a reminder that doors decide the result: by its calculation, an STC 40 wall with an open door covering 10 percent of its area performs like an STC 10 partition.
Small rooms near the open floor
Enclosed rooms do not have to be large. GSA’s guide describes workplace projects that “incorporated small enclosed rooms for privacy and concentration” alongside open work areas. A small room close to the desks means a confidential or long call does not require a walk across the building. Inside, it needs the same echo treatment as any meeting room, since hard small rooms sound boxy on calls; outside, its walls, door and glazing decide whether the conversation stays in.
The sibling article on NRC versus STC explains why absorption ratings and sound-blocking ratings come from different tests, and why panels inside a room cannot give its walls an STC.
Sound masking vs acoustic panels: a decision table
Use the table below as a first sort. Each row starts from the complaint people actually make and ends with the measure to check before you spend.
| What people say | What to measure first | Likely answer |
|---|---|---|
| "It's loud and echoey, it gets worse as the day goes on" | Reverberation time; ceiling NRC or coverage | Absorb: ceiling first, then walls near talkers |
| "I have to raise my voice on calls" | Reverberation time; background level | Absorb; check that the background is not already high |
| "I can follow every word two desks away" | Background level at ear height; ceiling performance | If the ceiling meets the guidance: cover (masking). If not: absorb first, then cover |
| "I worry people hear my calls" | Layout, screen height, background level | Block and cover: screens, distance, masking; call rooms for long calls |
| "The new office is so quiet I can hear a pen drop" | Background level | Cover, with absorption already in place |
| "The collaboration area drowns out the quiet zone" | Distance between zones; ceiling over both | Absorb over both zones and separate them; masking near the quiet zone |
| "Meetings in the glass room can be heard in the corridor" | Wall, door and glazing ratings; corridor background | Block (seals, glazing); cover outside the room; absorb inside only for echo |
| "Some conversations must stay confidential" | Which conversations, how often | Enclosed rooms with rated walls and doors |
Questions to ask before you buy either
Before you order panels or a masking system, collect enough information to know which problem you have. The cheapest mistake is the one you do not make.
Measure the floor
- Reverberation time at several points, or an estimate from the floor’s size and finishes.
- Background level in dBA at seated ear height, at a quiet time with ventilation running. Use a sound level meter that meets ANSI S1.4, the specification Cornell’s design standard cites, set to A-weighting, and take readings at several desks rather than one, since the background varies across a floor.
- Ceiling type and performance: NRC of the tile, or the coverage of clouds and baffles under a deck.
- Screen heights and the distance between teams that talk and people who need quiet.
- Which complaints are about noise and which are about overheard words.
Ask a panel supplier
- Which surfaces will be treated, and what reverberation time the plan expects, with the arithmetic.
- The ASTM C423 report behind every product, with the mounting type and, for baffles, the per-unit values.
- What the plan will not fix, in writing.
Ask a masking supplier
- Who designs and tunes the system, and to what spectrum.
- The target level in each zone, including meeting rooms, and how it combines with ventilation noise.
- The uniformity tolerance and how it will be measured after tuning.
- How occupants can adjust it in enclosed rooms, and within what limits.
Then decide
If the reverberation time is high or the ceiling is weak, fix that first and measure again. If the room is absorptive and quiet and people still follow conversations, bring in masking. If some conversations must stay private, plan rooms for them. Fibson’s acoustic design service turns a room estimate into a panel plan with a target, quantities and placement, and says in writing where blocking or masking is needed instead. The offices page describes what an office plan covers, and you can send your floor plan and ceiling photos for a written estimate.