For rooms used mainly for talking, published US limits put most offices, meeting rooms and classrooms between about 0.5 and 0.8 seconds of reverberation: LEED v4.1 asks for under 0.6 s in conference rooms and private offices and under 0.8 s in open offices without masking, and the classroom standard ANSI/ASA S12.60 sets 0.6 to 0.7 s. No US code sets a target for restaurants or homes, so those are planning choices; around 1 second or a little below is a common goal for dining rooms, and research ties the right figure to how many people share the room’s volume. Every one of these numbers is a mid-frequency value, usually for a furnished but empty room, and the right figure grows with room size.
The rest of this article gathers those sources in one table, explains the fine print that makes published charts disagree, checks the panel rules of thumb against Sabine’s formula, and shows how a target becomes a panel count. Fibson Acoustics plans rooms this way before anything is ordered: the acoustic design step starts with a target and the reasoning behind it.
What a reverberation time target actually specifies
A reverberation time target is a maximum decay time for sound in a room, stated at particular frequencies and for a particular state of the room. Reading the conditions matters as much as reading the number, because two charts can quote different seconds for the same room type and both be right.
Reverberation time, RT60 or T60, is the time sound takes to fall by 60 decibels after the source stops. A 1938 National Bureau of Standards circular defined it as the time for a sound to decrease “to one millionth of its initial value, or 60 decibels” (NBS Circular C418). Sabine’s formula estimates it from the room: RT60 = 0.049 × V ÷ A in feet, where V is the volume in cubic feet and A is the total absorption in sabins, or 0.16 × V ÷ A in meters (HyperPhysics, Sabine formula).
Four conditions to read with any target
- Frequency. LEED v4.1 states its limits “at 500 Hz, 1000 Hz, and 2000 Hz.” The site’s example room is estimated at 500 to 1,000 Hz. A target without frequencies cannot be compared with a measurement.
- Occupancy. The classroom standard’s limits are for “unoccupied classrooms,” as the U.S. Access Board summarized them, and Rindel’s restaurant criteria use the room “furnished but unoccupied.” People absorb sound, so a full room decays faster than the number on paper.
- Maximum or target. Most published values are ceilings, written “under 0.6 s” or “0.6 seconds maximum.” A plan can aim lower where the budget and the room allow.
- Estimate or measurement. A Sabine estimate predicts; a measurement checks. Cornell’s design standard asks for Sabine calculations during design and measurement after construction under ISO 3382-2, the international method for reverberation time in ordinary rooms (Cornell 098000 Acoustics; ISO 3382-2 catalogue page, archived copy). How to measure your own room, and how far to trust a phone, is the subject of our guide to measuring reverberation time.
Published targets by room type
Four US sources give reverberation numbers for ordinary rooms: the LEED v4.1 acoustic performance credit, the legacy WELL v1 feature, Cornell University’s owner design standard and ANSI/ASA S12.60 for classrooms. They agree more than the charts that rank online suggest, once room size and masking are accounted for.
| Room type | Limit or target | Source | Conditions and notes |
|---|---|---|---|
| Conference room | Under 0.6 s | LEED v4.1 BD+C, Table 2 | At 500, 1,000 and 2,000 Hz |
| Conference room | 0.6 s maximum | WELL v1 Feature 78 | Page is marked as a legacy version |
| Office conference room | 0.5 s | Cornell 098000, Table 1 | Paired with NC 25 to 30 and an STI of 0.75 |
| Teleconference room | Under 0.6 s | LEED v4.1, Table 2 | Same frequencies |
| Executive or private office | Under 0.6 s | LEED v4.1, Table 2 | Same frequencies |
| Private office | 0.4 to 0.7 s | Cornell 098000, Table 1 | Range rather than a single value |
| Shared office | 0.5 s | Cornell 098000, Table 1 | |
| Open-plan office without masking | Under 0.8 s | LEED v4.1, Table 2 | 0.8 s where sound masking is installed |
| Open office | 0.5 s maximum | WELL v1 Feature 78 | Legacy version |
| Classroom or meeting room under 10,000 cu ft | 0.6 s | Cornell 098000, Table 1 | 0.7 s from 10,000 to 20,000 cu ft |
| Classroom | 0.6 to 0.7 s | ANSI/ASA S12.60, per the Access Board summary | Unoccupied classrooms |
| Library | Under 1.0 s | LEED v4.1, Table 2 | Cornell lists 0.7 s |
| Hotel room or suite | Under 0.6 s | LEED v4.1, Table 2 | Useful reference for bedrooms |
| Hotel meeting or banquet room | Under 0.8 s | LEED v4.1, Table 2 | Useful reference for event dining |
| Food facility | 0.6 to 1.5 s | Cornell 098000, Table 1 | Covers many kinds of food space |
| Lobby | 1.2 s | Cornell 098000, Table 1 | Atrium 1.5 s |
| Restaurant dining room | No code target | None | A planning choice; see the restaurant section |
| Living room or home office | No standard | None | Borrow from rooms with the same use |
Two patterns stand out. Rooms where people must understand speech at a distance, or over a microphone, cluster at 0.5 to 0.6 s; larger or busier rooms where some liveliness is acceptable sit at 0.8 to 1.5 s. And none of these documents is a building code: they are a green building rating system, a wellness standard, an owner’s own rules and a voluntary consensus standard.
Why two charts can disagree about the same room
If you compare reverberation charts online, the same room type can carry numbers anywhere from 0.4 to 0.8 seconds. Most of that spread comes from the fine print rather than from real disagreement about what sounds good.
- Different frequencies. A value averaged over 500 to 2,000 Hz is not the same as one at 500 Hz alone, or one averaged down to 125 Hz.
- Empty or full. A limit for an unoccupied room is stricter, in practice, than the same number for a room in use.
- Different room sizes collapsed into one line. A chart that says “classroom” without a volume hides the tiers Cornell and S12.60 apply.
- Different countries and purposes. Charts drawn from other national standards or from studio practice answer different questions from a US office or dining room.
- Masking or none. LEED’s open-office line changes with masking; a chart that drops the condition drops the reason for the number.
When two sources disagree, read their conditions first. Often they turn out to be describing different rooms.
Offices and meeting rooms
For an enclosed meeting room or private office, 0.6 s or less is the figure the US sources share, with 0.5 s as Cornell’s stricter value for conference rooms. Open offices are the one place the sources split, because masking and layout change what reverberation needs to do.
LEED v4.1 lists conference rooms, teleconference rooms and executive or private offices all at under 0.6 s. WELL v1 lists conference rooms at 0.6 s maximum, and Cornell sets 0.5 s for office conference rooms alongside a background noise criterion and a speech transmission index. If the room hosts video calls, aim for the lower end, because the microphone picks up the room’s reflections along with the voice. Our page on meeting and video-call rooms covers how a plan arranges panels around the seats and camera.
Why open-office numbers disagree
The open-office spread, from WELL v1’s 0.5 s to LEED’s 0.8 s, reflects different goals. LEED gives two lines, under 0.8 s without masking and 0.8 s with it, so the presence of a masking system changes the number. Open plans are also large, so the same coverage of absorption produces a longer decay than in a small room.
The WELL feature quoted here is from the legacy v1 page, which says so at the top. WELL v2 reorganized its sound requirements, and its current thresholds should be checked on the WELL v2 site; our article on WELL sound requirements walks through what changed.
Huddle rooms and phone booths
Small rooms have no line of their own in these sources, but they inherit the meeting room figures because they are used the same way: two to four people, often on a call. Their small volume works in their favor, since a few panels make a large difference to total absorption. Their close, parallel walls work against them: the 1938 NBS circular warned that if all the treatment in a small room goes on the ceiling, a “flutter” between bare walls can leave it far less effective than the arithmetic suggests. For these rooms, under 0.6 s is a sensible target, and where the panels go matters as much as how many there are.
Targets written as coverage instead of seconds
Some guidance skips reverberation time and specifies absorption directly. GSA’s office guide asks for ceilings with “a minimum NRC of 0.9 in open plan office areas and NRC 0.8 in meeting rooms,” and in conference, meeting and training rooms it asks for “absorptive panels on 25% of walls with a minimum NRC of 0.8” (GSA Sound Matters). That is easier to check on a drawing but harder to compare between rooms of different size, which is why a room plan converts it back to seconds.
Classrooms, training rooms and other speech rooms
For learning spaces the US anchor is ANSI/ASA S12.60, which the Access Board summarized as setting “reverberation time (0.6 to 0.7 seconds) for unoccupied classrooms.” Training rooms, seminar rooms and any room where one person speaks to many without amplification can borrow the same figures.
The standard’s own volume breakpoints sit behind a paywall, but Cornell’s table shows the same idea plainly: classrooms and meeting rooms under 10,000 cu ft at 0.6 s, from 10,000 to 20,000 cu ft at 0.7 s, and anything larger set case by case with an acoustical consultant. WELL v1 likewise allows learning spaces a slightly longer time above a size threshold. Bigger rooms get a little more time, partly because reaching the same decay in a larger volume takes far more absorption.
A prescriptive route with a standard behind it
LEED v4.1 for schools offers a shortcut for classrooms under 20,000 cu ft. Under Option 1, the “total surface area of acoustic wall panels, ceiling finishes, and other sound-absorbent finishes” must equal or exceed the room’s ceiling area, counting only materials with an NRC of 0.70 or higher. Option 2 is a calculation to the S12.60 method.
That is the only coverage rule in this article with a standard behind it, and it is deliberately limited to small classrooms. Applied to a 20 by 14 ft room with a 9 ft ceiling, it would add 280 sq ft of absorber, which in the meeting room example later in this article would take the estimate well under the 0.6 s classroom figure.
Restaurants, cafes and bars
No US code or rating system sets a reverberation target for restaurants, so any number is a planning choice. A target of about 1 second or a little less is a common starting point, and the most useful research ties the right figure to how many guests share the room’s volume.
The practical evidence is thin but consistent. A ceiling manufacturer’s published project profile of a beer-garden restaurant in Exton, Pennsylvania, quotes its principal scientist: “Recommended levels for this type of space are below one second,” with readings in the room “closer to 1.5 seconds” before treatment and about 0.9 seconds after (project profile, PDF). Cornell’s broad “food facility” category runs from 0.6 to 1.5 s, and LEED’s under 0.8 s for hotel meeting or banquet rooms is the closest rating-system figure to a busy dining room.
Rindel’s acoustic capacity
Jens Holger Rindel’s published work on restaurant acoustics explains why one number cannot fit every dining room (Rindel 2019). Noise from talking guests depends on the room’s volume, its reverberation time and the number of people, because each table raises its voice as the room gets louder. He defines a room’s “acoustic capacity” as the largest number of people who can still hold a conversation at 1 m, and approximates it as N = V ÷ (20 × T), with V in cubic meters and T the furnished, unoccupied reverberation time at 500 to 1,000 Hz.
Turned around, that gives a target in seconds that depends on volume per seat. Rindel suggests four classes, with the maximum reverberation time set at 0.025, 0.040, 0.063 or 0.100 seconds per cubic meter of volume per person, from class A down to class D. He also notes that “when a restaurant is fully occupied, it is typical that the acoustic capacity is exceeded by a factor of 2 or more.”
Example (fictional). The site’s example room, a 60-seat dining room of 13,200 cu ft, is not a Fibson project and its coefficients are planning assumptions. In meters, 13,200 × 0.0283 = 373.8 m³, or 373.8 ÷ 60 = 6.2 m³ per seat.
- Before treatment, at 2.34 s: acoustic capacity = 373.8 ÷ (20 × 2.34) = 373.8 ÷ 46.8 = about 8 people.
- After the panel plan, at 0.98 s: 373.8 ÷ (20 × 0.98) = 373.8 ÷ 19.6 = about 19 people.
- Rindel’s class D for 60 seats: 0.100 × 6.2 = about 0.62 s. Class C: 0.063 × 6.2 = about 0.39 s.
The plan’s 1 second target more than doubles the room’s acoustic capacity, which is a large improvement, but a full room is still about three times over it. Reaching class C would take about 646.8 ÷ 0.39 = 1,660 sabins, two and a half times the planned 662.8, which in this room means treating the entire ceiling and about a third of the walls with high-performing absorber. That is the honest picture: in a dense dining room, panels make conversation much easier, and seat count, table size and music level decide the rest.
Rindel’s own advice follows from the same model: give restaurants as much volume as possible, apply absorption to the ceiling and to parts of the walls, and keep the seating plan from exceeding the acoustic capacity by more than 25 percent. He also shows that shorter conversation distances help, with 0.7 m across a small table giving a 3 dB better signal-to-noise ratio than 1 m. Why rooms get louder as they fill, and how many guests a room can take, is covered in depth in our article on why restaurants are loud.
Questions to settle before picking a dining-room target
Because the right number depends on the room and the business, write down these facts first. They are the inputs Rindel’s model uses, and they are what a room plan needs anyway.
- Seats at a full service. Count the maximum, including the bar and any communal tables.
- Volume. Length, width and ceiling height, including any raised or open ceiling areas.
- Table sizes. Small two-tops keep conversations short; large rounds stretch them across the table.
- Music. Rindel suggests background music no louder than about 60 dB if conversation matters, since music adds to the noise people talk over.
- The look you want to keep. Exposed structure, glass storefronts and hard floors are design choices, and the target has to be reachable with the surfaces left over.
With those five answers, a planner can show what 1.2 s, 1.0 s or 0.8 s would take in panels, and the owner can choose with the cost and the look in view.
Bars, taprooms and cafes
Bars and taprooms often want more energy than a dining room, and Rindel’s appendix notes research linking louder music in bars with faster drinking, which is one reason owners do not always want them quiet. A small cafe with a loud espresso machine and a few tables is a different room again. In both, start from the dining-room range and decide deliberately whether you are planning for conversation at the table or for buzz at the bar.
Homes and home offices
There is no US standard for reverberation in homes, so the useful move is to borrow from rooms with the same use. A home office used for calls is a private office or a small teleconference room; a bedroom is a hotel room; an open-plan living space is somewhere between a hotel room and a small banquet room.
That borrowing points to concrete numbers. LEED v4.1 lists teleconference rooms and private offices at under 0.6 s and hotel rooms or suites at under 0.6 s, with hotel meeting or banquet rooms at under 0.8 s. A home office used for daily video calls can sensibly aim at 0.5 to 0.6 s; a living room or open kitchen can accept a little more, because a room people relax in can afford some liveliness and its larger volume makes a short decay harder to reach.
Example (fictional). A 12 by 10 ft home office with a 9 ft ceiling (1,080 cu ft) has a wood floor, painted gypsum walls and ceiling, a 24 sq ft window and a 21 sq ft door. With planning assumptions of 0.07 for the floor, 0.05 for gypsum and the door, 0.12 for the glass and 12 sabins for the desk, chair, bookcase and a small rug, it has 8.4 + 6.0 + 17.6 + 2.9 + 1.1 + 12.0 = 47.9 sabins. RT60 = 0.049 × 1,080 ÷ 47.9 = 52.9 ÷ 47.9 = 1.10 s.
For a 0.6 s target the room needs 52.9 ÷ 0.6 = 88.2 sabins, so 40.3 more. At 6.0 sabins for each 2 by 4 ft panel over gypsum, that is 6.7, rounded up to 7 panels, and the result is 52.9 ÷ 89.9 = 0.59 s. Seven panels is a modest amount of wall in a small room, which is why home offices are often the easiest rooms to fix.
Furnished rooms with sofas, curtains, beds and rugs already have a good deal of absorption, so many living rooms need little help. The rooms that need help are the hard ones: new builds with bare floors, double-height spaces, kitchens open to living rooms and stairwells. For those, the target matters less than finding the surfaces that drive the decay. Our page on acoustic panels for open-plan homes covers how rugs, curtains and panels share that work, and the page on home offices covers rooms used for calls.
Why targets rise with room size, and other fine print
A target is not a property of a room type alone. It depends on volume, on which frequencies you count, on how many people are present and on how well Sabine’s assumptions fit the room.
Volume
Bigger rooms decay more slowly for the same finishes, because sound travels farther between reflections. HyperPhysics puts it simply: “You won’t get a long reverberation time with a small room.” The 1938 NBS circular noted that “the greater the dimensions of the hall the more prolonged will be the reverberation time.” Standards respond by allowing larger rooms a little more time, as Cornell’s 10,000 and 20,000 cu ft tiers and WELL v1’s learning-space sizes do, and Rindel’s restaurant classes make volume per person part of the target itself.
Frequency
Most targets describe the middle of the speech range. LEED’s three bands and the 500 to 1,000 Hz estimate used in room plans both leave out the lowest octaves, where thin panels absorb least and where rooms often ring longest. If a room booms rather than echoes, ask for a band-by-band estimate rather than one figure, and compare it with the panel’s full coefficient table.
Occupancy
People are absorbers. The NBS circular, writing about auditoriums, observed that “almost any room will have passable acoustic properties with a capacity audience, but with half the seats empty, conditions may be very unsatisfactory.” Rindel uses 0.2 to 0.5 square meters of absorption per person depending on clothing. That is why targets are written for unoccupied rooms: the empty room is the worst case, and the only one you can measure on a quiet afternoon.
Example (fictional). Take the example dining room, which is not a Fibson project, and add 60 seated guests at Rindel’s middle value of 0.35 m² each. One square meter is 10.764 sq ft, so 60 × 0.35 × 10.764 = 226.0 sabins.
- Before treatment: 276.4 + 226.0 = 502.4 sabins, and RT60 = 646.8 ÷ 502.4 = 1.29 s, against 2.34 s empty.
- After the panel plan: 662.8 + 226.0 = 888.8 sabins, and RT60 = 646.8 ÷ 888.8 = 0.73 s, against 0.98 s empty.
A full room decays faster than the empty-room estimate in both cases. That is also why the example’s 1 second target sits a little above LEED’s 0.8 s for banquet rooms: it describes the room before the guests arrive.
Sabine’s limits
Sabine’s formula assumes sound spreads evenly through the room, and it works best in moderately absorptive spaces. HyperPhysics notes that it “tends to overestimate the reverberation times for enclosures of high absorption coefficient.” Long, low rooms and rooms with all the absorption on one surface can also behave differently from the estimate. Treat a Sabine result as a planning number, then check with a measurement after installation.
Do the panel rules of thumb hold up?
The rules of thumb you will see on panel sellers’ pages, such as panel area equal to a share of the floor area or coverage of 20 to 40 percent of the wall and ceiling surfaces, can land near a sensible answer in an ordinary room. They fail when the ceiling is high, the finishes are unusually hard or soft, or the target is strict, because none of them looks at volume and existing absorption at the same time.
The test below applies three common rules to the example dining room and to a hypothetical version of the same room with a 20 ft ceiling. Every panel is assumed at a coefficient of 0.80 covering painted gypsum at 0.05, so each square foot adds 0.75 sabins.
Example (fictional). Room A is the site’s example dining room: 40 by 30 ft, 11 ft ceiling, 13,200 cu ft, 276.4 sabins, 2.34 s now. Room B is the same footprint with a 20 ft ceiling and the same finishes: 24,000 cu ft, walls of 140 × 20 = 2,800 sq ft less 220 sq ft of glass, so 84.0 + 60.0 + 129.0 + 26.4 + 40.0 = 339.4 sabins, and RT60 = 0.049 × 24,000 ÷ 339.4 = 1,176 ÷ 339.4 = 3.46 s now.
| Rule | Room A panels | Room A result | Room B panels | Room B result |
|---|---|---|---|---|
| Panel area equal to 40% of floor area | 480 sq ft | 646.8 ÷ 636.4 = 1.02 s | 480 sq ft | 1,176 ÷ 699.4 = 1.68 s |
| 20% of wall and ceiling area | 548 sq ft | 646.8 ÷ 687.4 = 0.94 s | 800 sq ft | 1,176 ÷ 939.4 = 1.25 s |
| 40% of wall and ceiling area | 1,096 sq ft | 646.8 ÷ 1,098.4 = 0.59 s | 1,600 sq ft | 1,176 ÷ 1,539.4 = 0.76 s |
| Sabine, solved for 1.0 s | 494 sq ft | 1.00 s | 1,115 sq ft | 1.00 s |
The floor-area rule happens to hit about 1 second in Room A and misses by two thirds of a second in Room B, because it ignores the extra 10,800 cu ft. The wall-and-ceiling rule scales with surface area, so it does better in Room B, but its 20 to 40 percent band spans everything from 0.59 to 0.94 s in Room A. Only the calculation hits the target in both rooms.
The rule that does work
The reliable rule is Sabine’s formula turned around: the total absorption a room needs is 0.049 × V ÷ target, in sabins. Subtract what the room already has, and divide by what one panel adds. At a 1 second target that means about 0.05 sabins of total absorption per cubic foot of room, which is why volume, not floor area, sets the panel count.
The table turns common targets into total absorption per 1,000 cu ft of room, straight from 0.049 × 1,000 ÷ target. Multiply by the room’s volume in thousands of cubic feet, then subtract what the room already has.
| Target RT60 | Total absorption needed per 1,000 cu ft |
|---|---|
| 0.5 s | 98 sabins |
| 0.6 s | 82 sabins |
| 0.8 s | 61 sabins |
| 1.0 s | 49 sabins |
| 1.2 s | 41 sabins |
| 1.5 s | 33 sabins |
For the 13,200 cu ft example dining room, a 1.0 s target means 13.2 × 49 = 647 sabins in total, matching the 646.8 worked out on the example room page.
Sabine’s own experiments, collected and published after his death, showed how dependable that inverse relationship is: across rooms of very different “size, shape and material,” the duration of the residual sound followed what he called “the hyperbolic law of inverse proportionality” with the absorbing material present (Sabine, Collected Papers on Acoustics). More absorption always shortens the decay in proportion; the only question is how much the room already has.
From a target to a panel count
Once you have a target, the panel count is arithmetic: absorption needed minus absorption present, divided by what each panel adds. The reverberation time calculator gives the starting point from the room’s finishes, and the panel quantity calculator does the rest; the example below shows the steps so you can check either one.
Example (fictional). A 20 by 14 ft meeting room with a 9 ft ceiling is used for video calls. Volume: 20 × 14 × 9 = 2,520 cu ft. The planning assumptions are carpet at 0.25, a painted gypsum ceiling at 0.05, 492 sq ft of gypsum walls at 0.05, 120 sq ft of glass at 0.12 and 15 sabins for the table and chairs.
- Absorption now: 280 × 0.25 + 280 × 0.05 + 492 × 0.05 + 120 × 0.12 + 15 = 70.0 + 14.0 + 24.6 + 14.4 + 15.0 = 138.0 sabins.
- RT60 now: 0.049 × 2,520 ÷ 138.0 = 123.48 ÷ 138.0 = 0.89 s.
- Target: under 0.6 s, the LEED v4.1 figure for teleconference rooms. Absorption needed: 123.48 ÷ 0.6 = 205.8 sabins.
- To add: 205.8 minus 138.0 = 67.8 sabins.
- Option 1, wall panels 2 by 4 ft at an assumed 0.80 over gypsum: 8 × 0.75 = 6.0 sabins each, so 67.8 ÷ 6.0 = 11.3, rounded up to 12 panels.
- Option 2, ceiling clouds 4 by 4 ft at an assumed 0.90, covering nothing: 16 × 0.90 = 14.4 sabins each, so 67.8 ÷ 14.4 = 4.7, rounded up to 5 clouds.
- Check: 138.0 + 72.0 = 210.0 sabins, and 123.48 ÷ 210.0 = 0.59 s.
The coefficients are assumptions for illustration. In a real plan each one comes from a published ASTM C423 report for the product, tested in a mounting that matches how it will hang.
Notice what the count does not tell you: where the 12 panels or 5 clouds should go. Sabine’s formula treats absorption as if location did not matter, which is close to true for the overall decay and not true for echoes between parallel walls or reflections near a microphone. Placement is its own decision, and it is the next step after the number.
Setting your own target: a checklist
A good target is written down with its reasoning, so anyone can see why it was chosen and check it later. Use these steps for each room.
- Name the main use. Meetings and calls, teaching, dining, focused work or relaxing. The use decides which row of the table applies.
- Find the nearest published figure. Use the table above. If a project is pursuing LEED or WELL, its required values take over; check WELL v2 directly rather than relying on the legacy v1 page.
- Adjust for volume. For rooms much larger than a typical office or classroom, allow a little more time, as Cornell’s tiers do. For restaurants, work out volume per seat and look at Rindel’s classes.
- State the frequencies and the room state. Write, for example, “0.6 s or less at 500 to 2,000 Hz, furnished and unoccupied.”
- Estimate the room now. List every surface, its area and an absorption coefficient, add furnishings, and run Sabine. The reverberation time calculator does this.
- Size the treatment. Absorption needed minus absorption present, divided by what each panel adds, using coefficients from test reports with the right mounting.
- Plan to check it. Measure before and after if you can, or keep the estimate and the assumptions so a later measurement can be compared fairly.
If you would rather have this worked out on paper, send the room’s dimensions, photos of each surface and how it is used through our contact page. The written estimate shows the surface inventory, the target and its source, and the arithmetic, before anything is ordered.