Fibson homePlan my room
Menu

Bar and taproom acoustics: concrete, steel and a crowd

Taproom acoustics for concrete, steel and glass rooms: where baffles, clouds and wall panels go when the industrial look stays, plus spills and staff limits.

A felt hop vine with soft olive leaves climbing along a charcoal steel girder studded with rivets, a few saffron hop cones hanging from it.
Reader question
Our bar or taproom has concrete floors, a hard ceiling and loud peaks. Where does treatment go when the industrial look must stay?

In a bar or taproom, treatment goes first where the crowd is densest and the staff work longest: over the bar and the standing zones, as ceiling baffles or clouds hung between the exposed services. Where the ceiling is historic, too crowded or off limits, the walls above head height carry the absorption instead, and in a tall room they have enough area to do it. Keep every panel out of the splash and lean zones, pick finishes that can be cleaned after closing, and treat the noise as a staff hearing question as well as a guest comfort one.

Bars and taprooms are not loud dining rooms. They combine the hardest finishes (sealed concrete, steel, glass, brick and an exposed deck) with standing crowds, music and a long working shift behind the bar. This guide, for owners of bars, breweries and taprooms and the designers who fit them out, covers why these rooms get so loud, how to map the noise, where treatment goes first, how to keep the industrial look, what to do when the ceiling cannot be touched, which finishes survive spills and humidity, and what workplace noise limits mean for bartenders. For seated dining rooms, see our guide on how to make a loud restaurant quieter.

Why are bars and taprooms louder than dining rooms?

Bars pack more people into the same floor, give them harder surfaces to talk over, and often add louder music. Each of the three adds decibels on its own, and together they push most busy bars well past the point where conversation is easy.

More people per square foot

A standing crowd is much denser than a seated one. In the 2021 International Building Code, as printed in Seattle’s adopted code, Table 1004.5 allows one occupant per 15 net sq ft for areas with tables and chairs, and one per 5 net sq ft for standing space. That is an exit figure, not a comfort target, but it shows the difference: the same floor can legally hold three times as many people standing.

Rindel’s 2019 review in Acoustics in Practice puts crowd noise at about 6 dB more for each doubling of the number of people, because everyone raises their voice over everyone else. Tripling the crowd at the same absorption adds about 20 × log10(3) = 9.5 dB in his simple model, somewhat less once the crowd’s own clothing is counted as absorption. A standing bar area full on a Friday is a different acoustic room from the same area set with tables.

Rindel’s own measurements include a reception in a hard, high university hall of about 8,265 cubic meters with a reverberation time of 3.9 seconds. With about 250 guests, the measured level over 15 minutes was 77 dB, against 78 dB predicted by his model. For 500 and 1,000 guests in the same hall, the model gives about 82 and 85 dB. At the earlier welcome party in that hall, with several hundred people and background music, he reports that conversation was extremely difficult.

Harder rooms

Taprooms often sit in old warehouses or new shells with sealed concrete floors, steel, brick, glass roll-up doors and an exposed deck. None of these absorb much sound. A ceiling manufacturer’s published project report on a Pennsylvania beer hall describes the pattern: exposed structure and concrete floors chosen for the look, and an owner who realized in opening week that the room was a problem, after a customer compared it to “eating on a tarmac waiting for a plane to take off.”

Glass, steel and parallel brick

Some taproom surfaces cause trouble beyond their hardness. A glass roll-up door or storefront reflects most of the sound that reaches it and cannot be treated, so the ceiling near it and the wall it faces carry the absorption. Long parallel brick or block walls can trap a flutter echo, a rapid ring between the two surfaces, which a band of panels on one wall breaks up. A stainless back bar, steel bar front and rows of kegs reflect sound straight back at the bartenders. None of this needs to change for the look to stay; it changes where the absorption goes.

What measurements show

  • Manhattan bars averaged 81 dBA. In Scott’s 2017 paper for the Acoustical Society of America, crowd-sourced readings from the SoundPrint app on prime-time evenings in 2015 to 2017 put bars at 81 dBA on average, against 78 dBA for restaurants. About 90 percent of bars measured were in the app’s categories that are not conducive to conversation, and about 60 percent in its categories considered potentially dangerous to hearing.
  • Loud venues averaged over 90 dBA. A New York City health department pilot study (Spira-Cohen and colleagues, 2017) measured 59 loud restaurants, bars, clubs and lounges. Restaurants and bars averaged 91 dBA, clubs and lounges 97 dBA. More patrons meant higher levels, and levels were higher from 9 pm on.

Some loudness is the product

Not every bar wants a quiet room. Rindel notes that in a bar, where guests come mainly for drinks, a noisy environment may be acceptable or even wanted, and our article on why restaurants get so loud summarizes the research on music and drinking. The goal in most taprooms is not quiet; it is a room where people can still talk to the person beside them and staff can still hear an order, without the noise climbing all night.

How loud is too loud in a bar, for guests and for staff?

For guests, the useful line is conversation with the person next to you; for staff, it is the workplace exposure limits. A bar can pass the first and still fail the second, because bartenders are there all shift.

For guests

  • Conversation at close range. In Rindel’s analysis, conversation at 0.5 meters (the person beside you) stays “sufficient” up to a background of about 83 dB; at 1 meter (across a small table or a corner of the bar), up to about 71 dB.
  • What bar guests accept. SoundPrint’s analysis of more than 10,000 user readings found the median level that users rated “moderate” for conversation was 77 dBA in nightlife venues, against 75 dBA in restaurants. These are crowd-sourced phone readings, not calibrated measurements.

For staff

  • OSHA. Under 29 CFR 1910.95, the permissible exposure is 90 dBA averaged over 8 hours, and the allowed time halves for every 5 dB above that. At an 8-hour average of 85 dBA, the action level, employers must run a hearing conservation program and make hearing protectors available to the exposed employees at no cost.
  • NIOSH. The NIOSH recommended exposure limit is 85 dBA over an eight-hour shift, with a 3 dB exchange rate: each 3 dB increase halves the recommended time.
Average level behind the bar NIOSH recommended maximum time OSHA permissible time
85 dBA 8 hours 16 hours (action level at 8 hours)
88 dBA 4 hours about 10.6 hours
91 dBA 2 hours 7 hours
94 dBA 1 hour about 4.6 hours
97 dBA 30 minutes 3 hours

NIOSH times follow from its 3 dB exchange rate; OSHA times are from 29 CFR 1910.95 Table G-16 and the reference durations in Table G-16a.

Guests count too, though their exposure is shorter. A two-hour visit at 91 dBA already reaches the NIOSH recommended daily maximum. The Spira-Cohen study found that in 49 percent of the loud venues, the measurement visit alone exceeded the maximum daily dose under the NIOSH limit.

Map the room before you treat it

Before choosing products, find out where the noise is loudest and how long sound lingers. A noise map and a reverberation estimate take an evening and a calculator, and they tell you where the first panel should go.

A noise map for a bar

NIOSH describes a simple noise map for workplaces, and it adapts well to a bar.

  1. Pick a typical busy night, with the usual music level and the usual crowd.
  2. Walk the floor with a sound level meter, taking readings every few feet where the level changes: behind the bar, at the service well, along the rail, in the standing zone, at tables, near speakers and the glass washer.
  3. Hold each reading for at least 30 seconds to average out bursts, as NIOSH advises.
  4. Write each level on a floor plan, with where staff stand and for how long.
  5. Mark the hot spots. These are where staff exposure and guest complaints start, and where treatment and speaker changes go first.

NIOSH recommends a Type 1 or Type 2 sound level meter for workplace measurements. A phone app is enough to rank spots against each other, but not to judge compliance; for that, use a calibrated meter or a personal dosimeter on the bartenders.

Example (fictional). These readings are invented to show the method, not measurements of a real bar. A brewery taproom maps a Friday at 8:30 pm with about 110 guests.

Spot Reading Who is there, and how long
Service well, behind the bar 89 dBA Two bartenders, most of a 7 hour shift
Bar rail, guest side 87 dBA Guests, 30 to 90 minutes
Standing zone under the main speaker 90 dBA Guests, staff passing
Tables by the roll-up door 82 dBA Guests, 1 to 2 hours
Merchandise corner 78 dBA One staff member, intermittent

The service well is the first priority: the bartenders spend most of a shift there, and an 89 dBA average over 7 hours would exceed the NIOSH limit. The map points to three moves: absorption over the bar and the standing zone, the main speaker re-aimed away from the service well, and a dosimeter test to confirm the real exposure.

A reverberation estimate

Reverberation time (RT60), the time a sound takes to fall by 60 dB, sets how much the crowd builds on itself. Sabine’s formula estimates it as RT60 = 0.049 × V ÷ A, with V in cubic feet and A in sabins. Big, hard taprooms often have long estimates, because as a room gets bigger its volume grows faster than its surface area. The manufacturer’s report above quotes its principal scientist: “Recommended levels for this type of space are below one second,” against readings “closer to 1.5 seconds” in the beer hall. No code sets a target for bars; treat it as a planning choice. Our reverberation time calculator does the arithmetic from your dimensions and finishes.

Where does treatment go first? Over the bar and the standing zones

Treat the ceiling over the bar and the standing area first, because that is where the densest crowd and the longest-staying staff are. Then extend treatment over the tables, and add wall panels where the ceiling runs out.

Why the bar comes first

The beer hall report is a fair example of the usual order. The treatment put acoustic clouds “over the loudest part of the bar,” panels in the rafters painted to blend into the structure, and an absorptive wall system with the restaurant’s logo on the front wall. The report says reverberation fell to 0.9 seconds, which it describes as a 30 percent reduction, and quotes a customer: “I can hear someone sitting next to me without them yelling.” It is one manufacturer’s account of one room, but the logic holds generally: absorption where the most people talk, and where staff spend the whole shift, does the most for the most people.

Baffles or clouds over an exposed deck

  • Baffles (vertical blades in rows) suit high, open decks with ducts, sprinkler mains and joists. Rows can run along the bar or between services. See ceiling baffles.
  • Clouds (horizontal panels) suit lower ceilings and areas where a flat plane reads better, such as over a lounge or a table zone. See ceiling clouds.
  • Comparing them fairly needs absorption per baffle or per cloud, not a coefficient per square foot. Our article on clouds versus baffles explains how to read the data sheets and how sprinklers affect each, and works through a fictional open-deck taproom with rows of baffles, so that example is not repeated here. The baffle layout calculator counts rows and spacing for a ceiling area.

Then the tables, the mezzanine and the walls

Once the bar and the standing zone are treated, extend baffles or clouds over the tables, at a lower density if the budget is tight. A mezzanine or a low section of ceiling needs attention of its own: the underside sits close to people’s heads, so it reflects voices strongly, and a few panels fixed to it do a lot. Keep the 80 inch headroom there, too. Finally, add wall panels above the lean zone where the ceiling treatment runs out, especially on long parallel walls.

Coordination that decides the layout

  • Sprinklers. Hanging panels must be coordinated with the sprinkler system. GSA’s Sound Matters guide notes that hanging panels “must also be coordinated with sprinkler systems and may require Fire Marshal approval.”
  • Headroom. The 2010 ADA Standards require 80 inches of clear headroom over circulation paths (section 307.4). In a taproom with an 18 ft deck this is easy; under a low mezzanine it decides the depth of any baffle.
  • Structure and services. Hang from structure that can take the load, clear of lights, diffusers, unit heaters and beer lines, and leave access to valves and junction boxes.
Section through a fictional taproom showing where treatment goesA cross-section, not to scale. An exposed deck runs across the top. Rows of vertical baffles hang over the bar on the left and over the standing zone in the middle. Fewer baffles hang over the tables on the right. Wall panels sit high on the left and right walls, above a band marked as the splash and lean zone that runs up from the floor. A dashed line marks 80 inches of clear headroom above the floor. Exposed deck, ducts and sprinkler mains Splash and lean zone: no panels 80 in clear headroom Bar Baffles over the bar Over the standing zone Fewer over tables Wall panels Wall panels Standing crowd Tables Ceiling baffles Wall panels above the lean zone Keep clear
Fictional example section for illustration, not to scale and not a Fibson project. Placement logic follows the noise map method above; the 80 inch headroom line is from the 2010 ADA Standards, section 307.4. The keep-clear band is a planning rule of thumb for splash, leaning and cleaning, not a code requirement.

How do you keep the industrial look?

Make the absorption read as part of the structure: in the color of the deck, aligned with the joists and ducts, or as a deliberate graphic element. Most of the hard materials that define the look (concrete floor, steel, brick, glass) can stay exactly as they are.

Moves that keep the character

  • Match the deck. Baffles and clouds in the deck’s color, hung in line with the joists, read as part of the ceiling. The beer hall’s rafter panels were “custom-fit-and-painted” to blend in.
  • Fill the bays. Panels set between exposed joists or purlins sit inside the structure’s own rhythm and leave the steel visible.
  • Keep the floor. A sealed concrete floor is part of the look and the cleaning routine. Leave it, and put the absorption overhead and high on the walls.
  • Use one wall as a feature. A wall of printed panels with the brewery’s artwork or label art, or a band of fabric-wrapped wall panels in a strong color, can be the room’s signature. Printed art panels carry an image you own or have licensed on an absorptive core.
  • Let felt play the material. Solid-color felt baffles in charcoal, olive or rust sit comfortably next to steel and brick.
  • Leave the showpieces alone. The brewhouse window, a historic sign or a restored ceiling can stay untouched if the treatment goes elsewhere.

What usually spoils the look

Panels that are randomly placed, slightly misaligned with the structure, or in a color that is neither the deck nor a deliberate accent tend to read as an afterthought. A ceiling plan drawn against the joist and duct layout before ordering avoids that.

What if the ceiling cannot be treated?

Put the absorption on the walls, high up. In a tall room, the walls above the lean zone add up to more area than most owners expect, and walls alone can take a very live room most of the way to a comfortable one.

Why the ceiling may be off limits

  • Historic ceilings: pressed tin, decorative plaster or an old timber deck a landlord or preservation review will not allow you to cover.
  • Crowded services: sprinkler mains, ductwork, beer lines and lighting with no clear bays.
  • Fire and structure: a deck that cannot take the added load without engineering, or a sprinkler layout that rules out obstructions.

Example (fictional). Not a Fibson project and not a real bar. A taproom in an old brick building, 50 by 25 ft with a 16 ft pressed-tin ceiling the owner will not cover. Volume 20,000 cu ft. Mid-frequency (500 to 1,000 Hz) coefficients are planning assumptions, not test results.

Surface or panel group Area (sq ft) Coefficient Sabins
Floor, sealed concrete 1,250 0.02 25.0
Ceiling, pressed tin 1,250 0.05 62.5
Walls, exposed brick 2,200 0.03 66.0
Storefront glass 200 0.12 24.0
Bar, stools, tables (allowance) 40.0
Total now 217.5
28 panels, 4 by 4 ft, high on both long walls 448 net 0.77 345.0
12 panels, 4 by 4 ft, on the end wall 192 net 0.77 147.8
10 panels, 2 by 4 ft, behind the bench seating 80 net 0.77 61.6
Total with panels 771.9

Now: RT60 = 0.049 × 20,000 ÷ 217.5 = 980 ÷ 217.5 = 4.51 seconds. Long walls only: 980 ÷ 562.5 = 1.74 seconds. Long walls and end wall: 980 ÷ 710.3 = 1.38 seconds. All three groups: 980 ÷ 771.9 = 1.27 seconds. Panels are assumed at 0.80, replacing brick at 0.03, so each square foot adds a net 0.77. Reaching 1.0 second would take 980 sabins in total, about 208 more, or roughly 270 sq ft of additional panels.

Estimated reverberation time of the fictional brick taproom with wall panels onlyHorizontal bars of mid-frequency RT60 in seconds. As built: 4.51. Long walls only: 1.74. Long walls and end wall: 1.38. All three wall groups: 1.27. A dashed line marks 1 second. 1 s As built 4.51 s Long walls only 1.74 s Long and end walls 1.38 s All wall groups 1.27 s 0 1 2 3 4 5 Mid-frequency RT60, seconds (Sabine estimate)
Fictional example data for illustration: a 50 by 25 by 16 ft brick taproom with an untreated pressed-tin ceiling, Sabine estimate RT60 = 0.049 × V ÷ A with planning-assumption coefficients, not test results and not a Fibson project.

What the example shows

  • Walls can carry it. At 16 ft, each long wall offers a band of several hundred square feet above the lean zone. The long walls alone take the room from 4.51 to 1.74 seconds.
  • The last half second is the hardest. Going from 1.27 to 1.0 second needs about a third more panel area again. Upholstered booths, a felt-wrapped bench back or a second art wall can supply it.
  • A packed room still runs loud. In Rindel’s model with this room’s volume, 60 guests would produce about 85 dB of crowd noise before treatment and about 78 dB after, at the edge of the range where his model applies. In the model, the gap between the untreated and treated room shrinks as the crowd grows, from about 8.5 dB at 30 guests to about 7 dB at 60, because the crowd’s own clothing adds absorption.

Wall panels along walkways must stay within the ADA’s 4 inch projection limit between 27 and 80 inches above the floor (section 307.2); above 80 inches, that limit does not apply. Our ADA protrusion checker does the check.

Which finishes survive spills, humidity and cleaning?

Keep panels out of reach of spills, leaning shoulders and the glass washer’s steam, choose faces that can be vacuumed and spot-cleaned, and treat the bar itself as a food preparation area. The FDA Food Code draws that line.

What the Food Code says

The FDA Food Code, a model code adopted in some edition by state and local health departments, defines food to include beverages and ice. In the 2026 edition:

  • Section 6-101.11 requires indoor floor, wall and ceiling surfaces to be smooth, durable and easily cleanable where food establishment operations are conducted, and nonabsorbent in areas subject to moisture, such as food preparation and warewashing areas.
  • Section 6-201.17 allows wall and ceiling surfaces and decorative items provided for ambiance in a consumer area to be exempt from the easily cleanable requirement for attachments, if they are kept clean.
  • Section 6-501.12 asks that routine cleaning happen when the least food is exposed, such as after closing.

So the back bar, the service well and the glass washing station need nonabsorbent surfaces; the guest side of the room can carry fabric, felt and wood panels kept clean. Ask your health inspector before putting any panel on the staff side of the bar.

Zones to keep clear

Zone What happens there Rule for panels
Service well and back bar Spills, ice, steam from the glass washer No absorptive panels; nonabsorbent surfaces
Bar rail and bar front Kicks, spills, leaning No panels; durable, wipeable bar front
Standing zone walls Shoulders, backs, drinks rested on ledges Panels start above shoulder height
Table zone walls Chair backs, elbows Panels above chair height, or durable fabric
Roll-up doors and patio openings Humidity, weather, rain blowing in Keep panels back from the opening
Brewhouse window or wall Heat and humidity from brewing Ask about humidity limits in the panel’s data

A cleaning routine that works

Panels in a bar collect dust, airborne grease from a kitchen and, near the bar, the odd splash. Write a routine before installation, not after: vacuum fabric and felt faces with a soft brush attachment on a set schedule, after closing; spot-clean only as the fabric maker’s instructions allow; and plan how staff will reach panels over the bar, with a ladder and a second person, without standing on the bar top. Where a panel will be touched often, ask whether its face can be replaced without replacing the core.

Fire and documentation

The International Building Code treats paneling applied for acoustical correction as interior finish (section 806.2 in the 2021 model code, as printed in Seattle’s adopted code), so it must meet the flame spread class your occupancy requires. Our article on acoustic panel fire ratings explains how the classes and test reports work, and the materials and safety page explains what to ask for. The local building official decides which edition applies.

What do the noise limits mean for bar staff?

They mean a busy bar should be measured as a workplace. Bartenders stand in the loudest part of the room for the whole shift, and research on restaurant workers suggests shift length matters as much as the level.

What the research shows

  • Loud venues exceed the NIOSH dose quickly. In the New York City pilot study, 80 percent of the 59 loud venues measured above 85 dBA, and in 49 percent the visit alone exceeded the NIOSH daily dose.
  • Long shifts drive exposure. A 2015 University of South Florida thesis by Gladieux measured 124 cooks, 119 servers and 91 dishwashers in nine high-volume restaurants. Cooks and dishwashers were the most likely to be overexposed; they typically worked more than 480 minutes, and minutes worked was the factor that explained their exposure. The study did not include bartenders, and its sample was small.
  • Bars are louder than restaurants. Scott’s data put bars about 3 dB above restaurants on average, and under NIOSH’s 3 dB exchange rate, 3 dB more halves the recommended time.

A shift worked through

Suppose a bartender works 7 hours at an average of 89 dBA, the service-well reading in the fictional noise map above. Under OSHA’s method, the reference duration at 89 dBA is 9.2 hours (Table G-16a), so the dose is 7 ÷ 9.2 = 76 percent. OSHA’s formula converts that to an 8-hour average: 16.61 × log10(0.76) + 90 = 88 dBA, below the 90 dBA limit but above the 85 dBA action level. Under NIOSH’s 3 dB exchange rate, 89 dBA allows about 8 ÷ 2^(4 ÷ 3) = 3.2 hours, so the same shift is about 220 percent of the recommended daily dose. The two agencies give different answers for the same shift because they use different exchange rates, which is why a dosimeter reading should say which criteria it was set to.

What an owner can do

  1. Measure the bartenders, not the room. A personal dosimeter over a full Friday shift gives the dose. A phone app does not.
  2. Re-aim or move speakers away from the service well, and give the bar its own speaker zone at a lower level.
  3. Treat the ceiling over the bar first, as above, so the reverberant level the staff stand in drops.
  4. Make hearing protectors available. At an 8-hour average of 85 dBA, OSHA requires employers to provide them at no cost.
  5. Rotate the loudest posts on live music nights, and keep long double shifts off the busiest nights where you can.

How do live music and DJ nights change the plan?

Live music and DJ nights are a different room. Rindel describes foreground music, meant to be listened to, at 75 to 90 dB, against 60 to 65 dB for background music, and guests are not expected to talk over it. Absorption still helps by keeping the room from muddying the sound and the crowd from building on top of it, but it will not make a band night quiet.

Plan for the music, not against it

  • Give the stage end its own treatment. Absorption on the wall behind the audience and over the stage area cuts the long reflections that blur a band in a hard room.
  • Do not fight bass with thin panels. Thin porous panels absorb far more in the speech range than at low frequencies: in Owens Corning’s data sheet for its 700 Series fiberglass board (ASTM C423, mounted against a solid backing), the 1 inch board absorbs 0.05 at 125 Hz against 0.88 at 1,000 Hz. Bass from a sound system needs thicker panels, air gaps or, more cheaply, a lower subwoofer level.
  • Set a level and keep it. A written maximum for the sound system, checked with a meter at the bar, protects staff on the nights when exposure is highest.
  • Plan the staff side. Hearing protectors, rotation and a speaker layout that does not fire straight at the service well matter most on these nights.

For the order of fixes in seated dining areas of a brewery restaurant, see how to make a loud restaurant quieter; for how table layout and zoning change things at equal covers, see our sibling article on table layout and restaurant noise.

Mistakes taprooms make with noise

The same few errors turn up in taproom after taproom.

  1. Covering the wrong wall. The brewhouse window and the logo wall are usually the room’s best features. Treat the ceiling and the plain walls first.
  2. Mounting panels at rail height. Panels where people lean, rest drinks or kick tend to get stained and torn. Start them above the lean zone.
  3. Relying on one feature wall. A single wall of panels in a large, hard room barely moves the estimate. In the fictional brick taproom, even both long walls left the room at 1.74 seconds.
  4. Fighting the sound system with panels. If the music is the loudest thing in the room, turn it down and re-aim it before buying absorption.
  5. Hanging baffles without the sprinkler contractor. A layout drawn without the heads on it may have to come down after inspection.
  6. Forgetting the staff. A room that guests call lively may still put the bartenders over the NIOSH limit on a Friday.

Questions to ask before you hang anything

A short list catches most of the problems that appear after installation.

  • Structure: what is each baffle or cloud hung from, and can it take the load, with the hardware the supplier specifies?
  • Sprinklers: has the sprinkler contractor marked the clearance to keep from each head, and will the fire official review the layout?
  • Data: does the absorption figure come from a test with the same mounting as your installation, with the method and edition named, and is it given per baffle or per cloud?
  • Fire: does the fire test report cover the panel as built, core, fabric and adhesive together, and what class does your occupancy need?
  • Cleaning: what can the face take (vacuum, damp cloth, nothing), and how will staff reach panels over the bar?
  • Color and alignment: is the layout drawn against the joists, ducts and lights so it reads as part of the building?

A taproom plan in six steps

Work in this order. The first two steps cost an evening; the rest give you a plan you can price.

  1. Map the noise. Walk a busy night with a meter, write levels on the floor plan, and note where staff stand and for how long.
  2. Fix the sound system. Re-aim or move speakers away from the service well, zone the bar, and write down a maximum level for normal nights and for music nights.
  3. Estimate the room. Measure length, width and height to the deck, list the finishes, and run the reverberation time calculator.
  4. Plan the ceiling over the bar and standing zone. Baffle rows along the bar and over the densest crowd, drawn against the joists, ducts, lights and sprinkler heads; use the baffle layout calculator for counts and spacing.
  5. Plan the walls. Panels above the lean zone on long walls, the end wall and behind bench seating, especially where the ceiling cannot be touched; one feature wall can carry the brand.
  6. Check documents and staff exposure. Ask for the absorption and fire test reports behind every panel, with method, edition and mounting, and book a dosimeter test for the bartenders.

The restaurants, cafes and bars page shows what a hospitality panel plan usually includes. Fibson designs and makes acoustic panels to order and plans each room before anything is ordered; if you want a second look at your taproom, send us the room with its dimensions, photos of the deck and walls, and your busiest-night headcount.

Working on a room like this?

Send the size, a few photos and what happens in the space. We reply with questions or an outline of the panel plan.

Plan my room